The largest database of trusted experimental protocols

Sensolyte 520 factor xa assay kit

Manufactured by AnaSpec

The SensoLyte® 520 Factor Xa Assay Kit is a fluorescence-based kit designed for the detection and quantification of Factor Xa activity. The kit utilizes a specific fluorogenic substrate that is cleaved by Factor Xa, releasing a fluorophore that can be measured using a fluorescence reader.

Automatically generated - may contain errors

2 protocols using sensolyte 520 factor xa assay kit

1

Factor Xa Inhibition Assay Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
The Factor Xa inhibition assay was carried out using a commercial SensoLyte® 520 Factor Xa Assay Kit (AnaSpec). The Factor Xa activity was assessed by its ability to cleave the fluorogenic FRET peptide and the subsequent unquenching by QXL 520 quencher of the 5-FAM fluorophore, which emits fluorescence. All extracts and controls were performed with three replicates in a 384-well plate format, each with a total reaction mixture of 12.5 μL. To begin, the test extracts and Thrombin/Factor Xa solution were incubated for five minutes then the substrate was added. After substrate addition and gentle mixing the reaction was incubated at room temperature for one hour. The fluorophore was detected with the use of a SpectraMax® Paradigm® Multi-mode Microplate Detection Platform (Molecular Devices) by scanning at 490 nm excitation wavelength and 520 nm emission wavelength.
+ Open protocol
+ Expand
2

Comparing Statin and Anticoagulant Efficacy

Check if the same lab product or an alternative is used in the 5 most similar protocols
To compare the magnitude of antithrombotic effect of statins to a conventional anticoagulant, additional mice (N = 32) with stasis IVC VT received subcutaneous low molecular treatment daily (enoxaparin 10 mg/kg SQ) for three days. Control mice received PBS. In addition, evaluation of combination daily statin (atorvastatin 1.14mg/kg or rosuvastatin 0.84 mg/kg) and enoxaparin 10 mg/kg LMWH therapy was examined. To verify the systemic anticoagulant effects of LMWH, factor Xa activity levels were measured in blood samples obtained four hours after the final LMWH injection, and (SensoLyte 520 Factor Xa Assay Kit, AnaSpec Inc.).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.