The largest database of trusted experimental protocols

Toledo ph probe

Manufactured by Mettler Toledo
Sourced in Switzerland

The TOLEDO pH probe is a precision instrument designed to accurately measure the pH of various solutions and liquids. It is a core component in laboratory equipment for conducting pH analysis and monitoring. The probe functions by detecting the hydrogen ion concentration in the sample and converting it into a measurable electrical signal.

Automatically generated - may contain errors

2 protocols using toledo ph probe

1

NMR Characterization of Ubiquitin Conformations

Check if the same lab product or an alternative is used in the 5 most similar protocols
Freeze-dried ubiquitin and diubiquitin samples were dissolved in 5% DMSO (Biosolve) in Milli-Q® water and then redissolved in NMR buffer containing 20 mM NaPO4 pH 6.8 and 10% D2O. Then, samples were taken in 15 ml 3.5 kDa Millipore spin filter tubes and spun-washed with three volumes of NMR buffer until DMSO was almost completely removed (LC/MS analysis). Concentrated samples were diluted to 500 μL with NMR buffer and the final concentration was determined using BCA assay using ubiquitin as standard. The pH was carefully measured using a Mettler TOLEDO pH probe.
All NMR studies were carried out on a Bruker 900 MHz spectrometer with a TCI cryoprobe, at 298 K (25°C). [1H, 15N] HSQC-spectra were acquired, processed and calibrated using standard methods. Chemical Shift Perturbations (CSPs) were calculated by comparing the [1H, 15N] HSQC spectra of mono Ub with that of each of the diUb molecules/ The CSP was calculated according to the following formula
where ΔδH and ΔδN are the chemical shift differences for 1H and 15N, respectively.
The spectra of K6 diUb indicated two different co-existing conformations. An “open conformation” was assigned based on similarity with the mono-Ub spectrum.
+ Open protocol
+ Expand
2

Isolation and Cultivation of Lactobacillus plantarum from Teff Injera

Check if the same lab product or an alternative is used in the 5 most similar protocols
L. plantarum strains B1.1 and B1.3 were previously isolated from Ethiopian teff injera (20 (link)) and were maintained as frozen glycerol stocks at −80°C. L. plantarum was routinely grown at 30°C in a commercial preparation of MRS (cMRS) (BD, Franklin Lakes, NJ), a modified MRS (26 (link)) (mMRS) prepared as lacking beef extract, mMRS supplemented with beef extract (8 g/L) (mMRS-BE), or a teff flour medium. To prepare the teff flour medium, whole-grain teff flour (Bob’s Red Mill, Milwaukie, OR) was sterilized by autoclaving for 1 h and then drying for approximately 15 h at room temperature. Teff flour medium was prepared by mixing the teff flour with phosphate-buffered saline (PBS; 137 mM NaCl, 2.7 mM KCl, 4.3 mM Na2HPO4·7H2O, 1.4 mM KH2PO4) (pH 7.2) at a dough yield [100 × weight (flour + PBS)/weight (flour)] (50 (link)) of 300. pH values were measured after 72 h of incubation in mMRS or mMRS with 5 mM CaCl2 using a Mettler Toledo pH probe (Mettler Toledo, Greifensee, Switzerland).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!