The largest database of trusted experimental protocols

Micromax 007hf cu

Manufactured by Rigaku

The Micromax™-007HF Cu is a compact X-ray diffraction (XRD) system designed for powder and thin-film sample analysis. It features a high-flux Cu X-ray source and advanced optics, providing efficient and accurate XRD data collection.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using micromax 007hf cu

1

Crystallization of PaFabA-N42FTA Complex

Check if the same lab product or an alternative is used in the 5 most similar protocols
N42FTA (1 mM) was incubated for 1 h with PaFabA at 7 mg/ml before setting the plates. Crystals appeared at 20 °C after 2 days from a hanging drop of 2 μl of protein solution with 1 μl of reservoir solution containing 0.1 M lithium sulfate, 12% polyethylene glycol MME 5000, and 0.1 M sodium citrate (pH 5). Crystals were cryoprotected by supplementing the mother liquor with 15% glycerol.
Data were collected in-house using a Rigaku Micromax™-007HF Cu anode with VariMax optics and a Rigaku Saturn 944 + CCD detector. Data were processed with xia2 [46] , [47] , [48] (link), [49] , [50] (link). The structure was solved using the coordinates of the wild-type PaFabA [42] (link) and the programme Phaser [51] (link). PHENIX [52] (link) was used for autobuilding from molecular replacement solution. The model was adjusted with Coot [53] (link) after each round of refinement in REFMAC 5.6 from the CCP4 programme suite 6.2.0 with local NCS restraints (option in programme) and TLS parameters [54] (link) applied throughout. N42FTA was added to the model when the difference electron density was clear (Fig. 6a). Coordinates and topologies of ligand were generated by PRODRG [55] (link). The quality of the structure was checked with MolProbity [56] (link). Final refinement statistics are given in Table 1. Figures were drawn using PyMOL [57] .
+ Open protocol
+ Expand
2

Macromolecular Structure Determination

Check if the same lab product or an alternative is used in the 5 most similar protocols
X-ray data were collected in-house using an R-AXIS IV++ image-plate system on a Rigaku MicroMax 007 HF Cu rotating-anode generator operating at 40 kV and 30 mA with Osmic VariMax HR optics. The crystal-to-detector distance was set to 100 mm and data were collected with oscillation steps of 1° (with an exposure time of 30 s) per image. The neutron crystal diffraction data were collected on the IMAGINE instrument, with a 20 h exposure time and images collected every 7°.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!