6 protocols using ir 200 spectrophotometer

1

Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reagentswere obtained commercially fromSigma-Aldrich and used without any further purification. The reaction was conducted at room temperature, unless otherwise noted [9 ]. The 1H and 13C NMR were recorded on a Bruker Advance II 400MHz NMR spectrometer with an indirect detection probe. Chemical shifts were reported in parts per million (ppm) from a standard of tetramethylsilane (TMS) in CDCl3 (0.1% w/v TMS) and coupling constants (J) are labeled in Hertz. Infrared spectrum was taken on a Thermo Electron Corporation IR 200 spectrophotometer and analyzed using EZ-OMNIC software.
+ Open protocol
+ Expand
2

Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
General Chemicals, Procedures and Instruments. The reaction was conducted at room temperature, unless otherwise noted [8 ]. Purification was accomplished by column chromatography, or high performance liquid chromatography. The 1H and 13C NMR were recorded on a Bruker Advance II 400 MHz NMR spectrometer with an indirect detection probe. Chemical shifts were reported in parts per million (ppm) from a standard of tetramethylsilane (TMS) in CDCl3 (0.1% w/v TMS). Signals in NMR spectra are defined as follows: s (singlet), d (doublet), t (triplet), m (multiplet), dd (doublet of doublets), pd (pseudo doublet), and all coupling constants (J) are labeled in Hertz. The mass spectra (MS) reported were obtained on a Bruker Esquire-HP LC/MS spectrometer in ESI+ detection mode. Samples were dissolved in methanol at a concentration of 1 mg/mL. Thin layer chromatography (TLC) was performed on oven dried Whatman aluminum-backed plates with varying eluent systems. Flash column chromatography was performed using oven dried 32 – 60 mesh 60-Å silica gel with varying eluent systems. A Perkin-Elmer 343 polarimeter was used to measure the optical rotation of all homogenous compounds. Infrared spectra were taken on a Thermo Electron Corporation IR 200 spectrophotometer and analyzed using EZ-OMNIC software.
+ Open protocol
+ Expand
3

Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reagentswere obtained commercially fromSigma-Aldrich and used without any further purification. The reaction was conducted at room temperature, unless otherwise noted [9 ]. The 1H and 13C NMR were recorded on a Bruker Advance II 400MHz NMR spectrometer with an indirect detection probe. Chemical shifts were reported in parts per million (ppm) from a standard of tetramethylsilane (TMS) in CDCl3 (0.1% w/v TMS) and coupling constants (J) are labeled in Hertz. Infrared spectrum was taken on a Thermo Electron Corporation IR 200 spectrophotometer and analyzed using EZ-OMNIC software.
+ Open protocol
+ Expand
4

Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
General Chemicals, Procedures and Instruments. The reaction was conducted at room temperature, unless otherwise noted [8 ]. Purification was accomplished by column chromatography, or high performance liquid chromatography. The 1H and 13C NMR were recorded on a Bruker Advance II 400 MHz NMR spectrometer with an indirect detection probe. Chemical shifts were reported in parts per million (ppm) from a standard of tetramethylsilane (TMS) in CDCl3 (0.1% w/v TMS). Signals in NMR spectra are defined as follows: s (singlet), d (doublet), t (triplet), m (multiplet), dd (doublet of doublets), pd (pseudo doublet), and all coupling constants (J) are labeled in Hertz. The mass spectra (MS) reported were obtained on a Bruker Esquire-HP LC/MS spectrometer in ESI+ detection mode. Samples were dissolved in methanol at a concentration of 1 mg/mL. Thin layer chromatography (TLC) was performed on oven dried Whatman aluminum-backed plates with varying eluent systems. Flash column chromatography was performed using oven dried 32 – 60 mesh 60-Å silica gel with varying eluent systems. A Perkin-Elmer 343 polarimeter was used to measure the optical rotation of all homogenous compounds. Infrared spectra were taken on a Thermo Electron Corporation IR 200 spectrophotometer and analyzed using EZ-OMNIC software.
+ Open protocol
+ Expand
5

Analytical Instrumentation Techniques

Check if the same lab product or an alternative is used in the 5 most similar protocols
The NMR spectra were obtained using an AVANCE 600 MHz instrument (Bruker Corporation, Switzerland). HRMS was determined using a 6520
quadrupole-time-of-flight mass spectrometer (Agilent, Palo Alto, CA). The UV data was obtained from a HITACHI U-3010 spectrophotometer (Hitachi Ltd, Tokyo, Japan), the IR spectrum and data obtained from IR200 spectrophotometer (Thermo Electron Corporation, Waltham, MA). In the separation process, the GF 254 (Qingdao Marine Chemical Co., Qingdao, China) was being as TLC filling, the silica gel
+ Open protocol
+ Expand
6

Comprehensive Analytical Techniques for Compound Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
The UV spectrum and data of absorbance were determined by using a HITACHI U-3010 spectrophotometer (Hitachi Ltd., Tokyo, Japan). The IR spectrum was obtained by using an IR200 spectrophotometer (Thermo Electron Corporation, Waltham, MA). The Circular dichroism spectra were obtained using J-810 Circular Dichroism spectrometer (JASCO Corporation, Japan). Optical rotations were measured with Autopol I automatic polarmeter (Rudolph Research Analytical, Hackettstown, NJ). The NMR spectra were recorded using an AVANCE 500 MHz instrument (Bruker Corporation, Switzerland). All compounds were dissolved in DMSO-d 6 or CDCl 3. Relative molecular mass were recorded by using a 6520 quadrupole-time-of-flight mass spectrometer (Agilent, Palo Alto, CA). Purity was detected on a Nexera X2 UHPLC LC-30A system (Shimadzu, Kyoto, Japan), using a Kromasil C18 column (150 mm × 4.6 mm, 5 μm, Dalian Johnsson Separation Science and Technology Corporation). The oven temperature was maintained at 40 °C. Water containing 0.1% formic acid served as solvent system A, and methanol served as solvent system B. The flow rate was 1.0 mL/min, and injection volume was 5 μL. 96-well microplate reader (HBS-1096A) was purchased from Nanjing Detie Experimental Equipment Co., Ltd. (Nanjing, China).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!