The largest database of trusted experimental protocols

Chemidocxrs gel imaging and analysis system

Manufactured by Bio-Rad
Sourced in United States

The ChemiDocXRS gel imaging and analysis system is a laboratory equipment designed for capturing and analyzing images of various types of gels, such as those used in electrophoresis. The system includes a camera, illumination sources, and software for capturing, processing, and analyzing the gel images.

Automatically generated - may contain errors

3 protocols using chemidocxrs gel imaging and analysis system

1

Donepezil Ameliorates Amyloid-beta-Induced Neurotoxicity

Check if the same lab product or an alternative is used in the 5 most similar protocols
Donepezil hydrochloride table (Lot: 110822A) was purchased from Eisai China Inc. (Suzhou, Jiangsu, China) and prepared to a mixed suspension at the concentration of 0.1 mg/mL. Aβ25–35 (Lot: Y-0044) was purchased from BIOSS Biotech Limited Company (Beijing, China). Streptavidin-biotin complex (SABC) and TUNEL apoptosis detection kits were purchased from BOSTER Biotech Limited Company (Wuhan, Hubei, China). An RT-PCR kit was purchased from TransGen Biotech Limited Company (Beijing, China). Anti-Bcl-2, anti-Bax, and anti-β-actin antibodies were purchased from Bio-Rad Laboratories, Inc. (Berkeley, CA, USA). The MT-2000 Morris water maze was purchased from Chengdu Taimeng Technology Co., Ltd. (Chengdu, Sichuan, China). A ZH-LAN-STAR C type brain stereotaxic apparatus was purchased from Huaibei Zhenhua Biological Equipment Co., Ltd. (Huaibei, Anhui, China). An inverted microscope S70 was purchased from Leica DMIRB (Lognes, France). A ChemiDocXRS gel imaging and analysis system was purchased from Bio-Rad Laboratories, Inc. (Berkeley, CA, USA). An SP-9000 immunohistochemistry kit was purchased from Beijing ZSGB Biological Engineering Co., Ltd. (Beijing, China). A TC-512 PCR amplification instrument was purchased from Techen (London, UK).
+ Open protocol
+ Expand
2

Donepezil Hydrochloride Alleviates Aβ25-35-Induced Neurodegeneration

Check if the same lab product or an alternative is used in the 5 most similar protocols
Donepezil hydrochloride tablets (lot: 110822A) were purchased from Eisai China and prepared in a mixed suspension at 0.1 mg/ml. Aβ25‐35 (lot: Y‐0044) was obtained from Bioss Biotech. Streptavidin–biotin complex and terminal deoxynucleotidyl transferase dUTP nick‐end labeling (TUNEL) apoptosis detection kits were purchased from Boster Biotech. A real‐time reverse transcription–quantitative polymerase chain reaction (RT‐qPCR) kit was obtained from TransGen Biotech. Antibodies against Bcl‐2 Bax, and β‐actin were purchased from Bio‐Rad Laboratories. A brain stereotaxic apparatus (ZH‐LAN‐STAR, C type) was obtained from Huaibei Zhenhua Biological Equipment. An inverted microscope (S70) was purchased from Leica. A ChemiDoc XRS gel imaging and analysis system was obtained from Bio‐Rad Laboratories. An SP‐9000 immunohistochemistry kit was purchased from Beijing ZSGB Biological Engineering. PCR amplification instrument (TC‐512) was from Techen. Detection kits for malondialdehyde (MDA), superoxide dismutase (SOD), glutathione (GSH) and ACHE were purchased from Nanjing Jiancheng Bioengineering Research Institute. Rabbit anti‐GFAP antibody (lot: 16825–1‐AP) was obtained from Proteintech. Rabbit anti‐IBA1 antibody (lot: bs‐1363R) was from Bioss Biotech.
+ Open protocol
+ Expand
3

Neuroprotective Effects of SLF in Alzheimer's Disease

Check if the same lab product or an alternative is used in the 5 most similar protocols
SLF was prepared at a concentration of 100 mg/mL at the School of Pharmacy, Southwest Medical University (Luzhou, Sichuan, China) using a 1.0 g suspension equivalent to 31.5 g crude material. After purchasing donepezil hydrochloride (lot: 110823A) from Eisai Inc. (Suzhou, Jiangsu, China), a 0.1 mg/mL concentration was prepared. Aβ25-35 (lot: Y-0044) was acquired from BIOSS Biotech Co., Ltd. (Beijing, China). Anti-AKT and anti-GSK-3β antibodies were purchased from Abcam (Cambridge, MA, USA). Anti-tau antibody was obtained from American Bioworld Co., Ltd. (Dublin, OH, USA). Anti-GAPDH antibody was purchased from Kangchen Bio-tech Inc. (Shanghai, China). The brain stereotaxic apparatus was purchased from Huaibei Zhenhua Biological Equipment Co., Ltd. (Anhui, Huaibei, China). The Morris water maze was purchased from Chengdu Taimeng Technology Co., Ltd. (Chengdu, Sichuan, China). An S70 Inverted microscope was purchased from Leica DMIRB (Rueil-Malmaison, France). The ChemiDocXRS gel imaging and analysis system was purchased from Bio-Rad Laboratories, Inc. (Berkeley, CA, USA). SP-9000 immunohistochemistry kit was purchased from Beijing ZSGB Biological Engineering Co., Ltd. (Beijing, China). ECL Western detection reagents were from 4A Biotech Co., Ltd. (Beijing, China).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer