Esquire hct ion

Manufactured by Bruker

The Esquire HCT ion trap mass spectrometer is a high-performance analytical instrument designed for sensitive and accurate mass analysis of a wide range of chemical compounds. It utilizes ion trap technology to capture, store, and analyze ions, providing precise mass determination and structural information.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using esquire hct ion

1

Optimized Mass Spectrometry Analysis of Arabidopsides

Check if the same lab product or an alternative is used in the 5 most similar protocols
An Esquire HCT ion trap mass spectrometer (Brüker) was used in electrospray + mode. Mass spectrometer conditions were optimized independently for oxidized MGDGs (arabidopsides A and B), oxidized DGDG (arabidopside D) and oxidized acyl-MGDG (arabidopsides E and G). The capillary voltage was set at − 4500 V, endplate offset at − 500 V, nebulizer pressure at 50 psi and the flow rate of the dry gas at 10 L min-1. Mass spectrometer optimized parameters that differed for the analysis of each arabidopside class are presented in Supplemental Table 1. The mass resolution was calculated for each arabidopside as the ration between the mass of the quantification ion and the width of that peak at 50% peak height. Mass resolutions were, respectively, of 1,585 for arabidopside A, 2,051 for arabidopside B, 1,975 for arabidopside D, 2,143 for arabidopside E and 2,199 for arabidopside G. Data treatment was performed using Brüker Daltonics esquire DataAnalysis software.
+ Open protocol
+ Expand
2

Mass Spectrometry Protocol for Biomolecules

Check if the same lab product or an alternative is used in the 5 most similar protocols
The HDM parameters are given for each experiment in the Results and Discussion section.
Samples were analysed on a Bruker Esquire HCT ion trap mass spectrometer. The mass range used was 100 -2800 m/z, in alternating polarity mode, using a maximum accumulation time of 200 ms and a Smart Target of 200,000. The capillary voltage was set to 4 kV and the source temperature set to 300 °C.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!