The largest database of trusted experimental protocols

Nicolet is50 fourier

Manufactured by Thermo Fisher Scientific
Sourced in United States

The Nicolet iS50 Fourier is a Fourier transform infrared (FTIR) spectrometer designed for analytical applications. It utilizes Fourier transform technology to analyze the infrared absorption spectrum of samples, providing information about their chemical composition and structure.

Automatically generated - may contain errors

Lab products found in correlation

3 protocols using nicolet is50 fourier

1

Corona Resistance of PI/SiO2 Thin Films

Check if the same lab product or an alternative is used in the 5 most similar protocols
Corona resistance tests were performed on PI/SiO2 films with different doping amounts using a corona resistance tester assembled according to IEC 60343 standards; conductance current tests were performed with EST122-picoammeter and HV-103P2 DC high voltage power supply; the SU8020 scanning electron microscopy (SEM)was used to characterize the morphology of the breakdown point of the film and surroundings after corona formation. The microstructures were characterized by using a Thermo Scientific Nicolet iS50 Fourier transform infrared spectrometer with an attenuated total reflection (ATR) accessory; the dielectric properties of the composite films were tested with an Alpha-A broadband dielectric spectrum analyzer.
+ Open protocol
+ Expand
2

IR Spectroscopy of Melanin Powder

Check if the same lab product or an alternative is used in the 5 most similar protocols
IR spectra were
acquired using the Thermo Scientific Nicolet iS50 Fourier transform
infrared spectrometer. The black knot (or the extracted melanin) powder
(approx. 1–2 mg) was ground with 160 mg of potassium bromide
(KBr, FTIR grade, Sigma-Aldrich) using an agate mortar and pestle.
The fine ground powder was compressed to a semi-transparent pellet
using a die and hydraulic press (OMEGA CN9000). The formed pellets
were placed in the vacuum oven at room temperature overnight to remove
any adsorbed water. The pure KBr pellet was used as the background
for obtaining the IR spectra of samples in the transmission mode.
An average of 32 scans were collected with a resolution of 4 cm–1 in the 400–4000 cm–1 range.
+ Open protocol
+ Expand
3

FTIR Analysis of Diluted Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
The measurements were performed using a Nicolet iS50 Fourier transform
infrared (FTIR) spectrometer from Thermo Scientific, USA running on
Omnics software. Each sample was diluted to 5 mg/mL (dilution factor
∼4 if concentration ∼20 mg/mL), and 6–8 μL
of the sample was loaded. The corresponding extraction buffer was
measured as a blank.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!