7 protocols using mcp 200

1

Spectroscopic and Chromatographic Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotation values were recorded on a polarimeter (Anton-Paar MCP 200; Austria). Infrared (IR) spectra were obtained with a Fourier transform infrared spectrometer (IFS-55; Bruker). A Shimadzu UV-1700 spectrophotometer (Shimadzu, Kyoto, Japan) was used to obtain the ultraviolet (UV) spectra. The NMR spectra were recorded using ARX-400 and AV-600 spectrometers (Bruker) with TMS as an internal standard. HRESIMS data were recorded on an Agilent G6520 Q-TOF spectrometer (Santa Clara, CA, USA). Column chromatography was conducted using silica gel (100–200 mesh and 200–300 mesh, Qingdao, China) and ODS (50 μm, Aichi, Japan) as absorbents, and thin-layer chromatography (TLC) plates (GF254) were purchased from Qingdao Marine Chemical Co. Ltd. (Qingdao, China). High-performance liquid chromatography (HPLC) was performed using a Shimadzu LC-20AR instrument equipped with an SPD-20A UV detector (Shimadzu, Kyoto, Japan) and a YMC Rp-C18 column (5 μm, 10 × 250 mm) (YMC, Kyoto, Japan). Cell apoptosis and intracellular ROS measurements were analyzed using a Becton Dickinson FACS Calibur System. All solvents used for isolation were of analytical grade, and the reagents for HPLC were of chromatographic grade.
+ Open protocol
+ Expand
2

Comprehensive Analytical Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were measured using an MCP 200 (Anton Paar, Shanghai, China) polarimeter. UV spectra were recorded on a Shimadzu UV-240 spectrophotometer (Shimadzu, Kyoto, Japan). The Chirascan-plus circular dichroism spectrometer (Applied Photophysics Ltd., Surrey, UK) was used for recording ECD spectra. IR spectra were recorded by a Fourier transformation infra-red spectrometer coupled with infra-red microscope EQUINOX 55 (Bruker, Rheinstetten, Germany). The 1D and 2D NMR spectra were recorded on Bruker Avance 400 spectrometer (1H 400 MHz, 13C 100 MHz). Chemical shifts (δ) were given in ppm with reference to the solvent signal (δC 39.52/δH 2.50 for DMSO), and coupling constants (J) were given in Hz. HR-ESIMS spectra were recorded on an LTQ-Orbitrap LC-MS spectrometer (Thermo Corporation, Waltham, MA, USA). ESIMS spectra were obtained on an ACQUITY QDA LC-MS spectrometer (Waters Corporation, Milford, MA, USA). Column chromatography (CC) was performed using silica gel (200–300 mesh, Qingdao Marine Chemical Factory, China) and Sephadex LH-20 (GE Healthcare, Littile Chalfont, UK) as stationary phases. HPLC was performed on an Essentia LC-16 (Shimadzu, Shanghai, China). Pre-coated silica gel plates (Qingdao Huang Hai Chemical Group Co., G60, F-254, China) were used for thin layer chromatography.
+ Open protocol
+ Expand
3

Optical Rotation Measurement Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotation values were recorded on a PerkinElmer 241 or Anton Paar MCP 200 polarimeter. The specific rotation is calculated as follows: [α]λφ=α100c-1d-1 . The wave length λ is reported in nm (sodium D line, λ = 589 nm), the measuring temperature ϕ in °C; α represents the recorded optical rotation, c the concentration of the analyte in g mL−1, and d the length of the cuvette in dm. Thus, the specific rotation is given in 10−1 deg cm2 g−1. The values for the specific rotation are reported as follows: specific rotation (concentration g 100 mL−1; solvent).
+ Open protocol
+ Expand
4

Analytical Characterization of Natural Products

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were carried out on an MCP 200 (Anton Paar, Graz, Austria) polarimeter. UV spectra were measured at a Lambda 950 UV-Vis-NIR spectrophotometer (PerkinElmer, Akron, OH, USA). A Chirascan-plus Circular Dichroism Spectrometer (Applied Photophysics Ltd., Leatherhead, UK) was used to obtain experimental ECD data. A Fourier transformation infra-red spectrometer (FTIR) coupled with an infra-red microscope EQUINOX 55 (Bruker, Wissembourg, France) recorded the FTIR spectrum. NMR spectra were tested by a BRUKER AVANCE III HD (400 MHz) NMR spectrometer with tetramethylsilane (TMS) as the internal standard. HR-ESIMS data were determined using an Agilent 6530 accurate-Mass Q-TOF LC-MS spectrometer. Column chromatography (CC) was used using silica gel (200–300 mesh, Qingdao Marine Chemical Factory, Qingdao, China). The semi-preparative HPLC was performed on an Essentia LC-16 (Shimadzu, Jiangsu, China). Acetylcholine esterase (AChE) was from Electrophorus electricus (product number: C3389-2KU, Sigma-Aldrich, Saint Louis, MO, USA).
+ Open protocol
+ Expand
5

Comprehensive Analytical Techniques for Natural Products

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were measured with an AntonPaar MCP 200 automatic polarimeter. Ultraviolet (UV) spectra were obtained on a UV-2550 spectrophotometer (Shimadzu Corporation, Tokyo, Japan). IR spectra were recorded on a Bruker Tensor 27 FT-IR spectrometer (film). 1D and 2D-NMR spectra were carried out on a Bruker AM-400 and an Avance-500 spectrometer, δ in ppm rel. to TMS, J in Hz. ESIMS and HRESIMS were measured with a Bruker miXis TOF-QII mass spectrometer (Bruker, Fällanden, Switzerland), respectively. Silica gel (100–200 mesh, 300–400 mesh, Qingdao Marine Chemical Ltd., Qingdao, China), Sephadex LH-20 (GE Healthcare Bio-sciences AB, Uppsala, Sweden), and YMC GEL ODS-A (S-50 μm, 12 nm) (YMC Co., Ltd., Kyoto, Japan) were used for column chromatography. Semipreparative HPLC analyses were performed using an ODS column (YMC-ODS-A, 250 × 20 mm, 5 μm). Circular dichroism (CD) spectra were measured on a Chirascan circular dichroism spectrometer (Applied Photophysics Ltd., Leatherhead, UK). MTT assays were analyzed using a microplate reader (BioTek Synergy H1, BioTek Instruments, Inc., Vermont, USA).
+ Open protocol
+ Expand
6

Comprehensive Analytical Techniques for Chemical Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were recorded on an MCP 200 (Anton Paar, Shanghai, China) polarimeter. UV data were measured on a Shimadzu UV-240 spectrophotometer (Shimadzu, Kyoto, Japan). IR spectra were detected on a Fourier transformation infra-red spectrometer coupled with infra-red microscope EQUINOX 55 (Bruker, Rheinstetten, Germany). 1D and 2D NMR spectra were performed on a Bruker Avance 400 MHz spectrometer with tetramethylsilane as internal standard. HR-ESIMS data were carried out on an LTQ-Orbitrap LC-MS spectrometer (Thermo Corporation, Waltham, MA, USA). ESIMS spectra were obtained on an ACQUITY QDA (Waters Corporation, Milford, MA, USA). HPLC was carried out on Essentia LC-16 with an SPD-16 Detector (Shimadzu, Shanghai, China). Column chromatography was performed on silica gel (200–300 mesh, Qingdao Marine Chemical Factory, China) and Sephadex LH-20 (GE Healthcare, Littile Chalfont, UK).
+ Open protocol
+ Expand
7

Determining Optical Rotations of Bisabolol Stereoisomers

Check if the same lab product or an alternative is used in the 5 most similar protocols
The stereochemistry of (−)-α-bisabolol, (+)-α-bisabolol, (+)-epi-α-bisabolol, (−)-β-bisabolol, and (–)-β-bisabolene reflects stereochemistry or specific rotation values reported in vendor certificates. We determined the specific rotation of (+)-α-bisabolene by using an Anton Paar MCP-200 polarimeter. In brief, we used the sodium D line at 589 nm with a cell path length of 100 mm. For α-bisabolene, we dissolved 12.18 mg of the colorless oil in 3.0 mL of CHCl3 (0.406 g/100 mL CHCl3), placed the resulting solution inside the cell, and allowed the temperature to equilibrate to 25 °C before collecting a reading.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!