The largest database of trusted experimental protocols

Sonoplus uw2070 hd 2070

Manufactured by Bandelin
Sourced in Germany

The Sonoplus UW2070 + HD 2070 is a laboratory equipment product. It is designed for ultrasonic homogenization and dispersion of samples. The device features a stable and powerful ultrasonic generator.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using sonoplus uw2070 hd 2070

1

Curdlan-Loaded PLGA Nanoparticle Synthesis

Check if the same lab product or an alternative is used in the 5 most similar protocols
An emulsion-solvent evaporation technique was developed to synthesize the NPs having varying densities of curdlan (2, 5 and 8% w/w).15 (link)–18 Briefly, 2 mL of a 1% w/v polymer solution (mixture of C-PLGA and PLGA) in a DMSO: DCM mixture (1:9) was added drop-wise to 10 mL of a PVA solution in de-ionised water (0.5% w/v) under probe sonication (Bandelin Sonoplus UW2070 + HD 2070 Berlin, Germany) for 7 min, 55% power, 70 Watt). A mixture of C-PLGA and PLGA was used to produce the desired concentration of curdlan functionalized NPs. For example, to synthesize 2% w/w curdlan loaded PLGA NPs, a ratio of 4 parts PLGA: 1-part C-PLGA was used. The same procedure was used to synthesize NPs containing 5% and 8% w/w curdlan loaded PLGA NPs. PLGA NPs were synthesized using only a solution of PLGA polymer. The solvent was subsequently removed in vacuo at 35°C and the NPs collected through centrifugation at 10 000 × g for 5 min, followed by washing once with de-ionized water and lyophilization over 72 h in the presence of sucrose (1% w/v) as a cryoprotectant.
+ Open protocol
+ Expand
2

Curdlan-Loaded PLGA Nanoparticle Synthesis

Check if the same lab product or an alternative is used in the 5 most similar protocols
An emulsion-solvent evaporation technique was developed to synthesize the NPs having varying densities of curdlan (2, 5 and 8% w/w).15 (link)–18 Briefly, 2 mL of a 1% w/v polymer solution (mixture of C-PLGA and PLGA) in a DMSO: DCM mixture (1:9) was added drop-wise to 10 mL of a PVA solution in de-ionised water (0.5% w/v) under probe sonication (Bandelin Sonoplus UW2070 + HD 2070 Berlin, Germany) for 7 min, 55% power, 70 Watt). A mixture of C-PLGA and PLGA was used to produce the desired concentration of curdlan functionalized NPs. For example, to synthesize 2% w/w curdlan loaded PLGA NPs, a ratio of 4 parts PLGA: 1-part C-PLGA was used. The same procedure was used to synthesize NPs containing 5% and 8% w/w curdlan loaded PLGA NPs. PLGA NPs were synthesized using only a solution of PLGA polymer. The solvent was subsequently removed in vacuo at 35°C and the NPs collected through centrifugation at 10 000 × g for 5 min, followed by washing once with de-ionized water and lyophilization over 72 h in the presence of sucrose (1% w/v) as a cryoprotectant.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!