The largest database of trusted experimental protocols

3 protocols using 6 aminoquinolyl n hydroxysuccinimidyl carbamate aqc

1

Determination of pH, Organic Acids, and Free Amino Acids

Check if the same lab product or an alternative is used in the 5 most similar protocols
The pH was measured by using a Sartorius pH indicator. Lactic acid, acetic acid, and free amino acids were determined by using ACQUITY UPLC M-Class System with BEH C18 Column (2.1 × 50 mm × 1.7 μm) and PDA detector (Waters Corporation, Milford, MA, USA). The supernatants of Suanzhou samples were subjected to filtration by the syringe filter (0.2 μm pore size). The filtrate was directly used for the lactic acid and acetic acid analysis. The mobile phase used was prepared by mixing 0.01 mol/l KH2PO4 (pH 3.0) and CH3CN in a ratio of 98:2. Free amino acids in the supernatant samples were determined according to the manual from Waters and the method described previously (Fiechter et al., 2011 (link)). The reagent 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC, Waters) was used to derivatize amino acids. Amino acids AAS18 and A9906 (Sigma-Aldrich) were used as analytical standards. All experiments were repeated three times. The values for pH, organic acids, and free amino acids were subjected to one-way analysis of variance (ANOVA) by Tukey's method of the statistical software Statistica 7.0.
+ Open protocol
+ Expand
2

Amino Acid Derivatization Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
All chemicals and reagents used in the study were of analytical or HPLC grade with the highest purity. Ortho-phthalaldehyde (OPA) was obtained from Millipore Sigma, St Louis, MO, USA. Amino acid derivatization reagent, 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC), part of the AccQ•TagTM Ultra Derivatization Kit (P/N 186003836), was obtained from Waters Corp., Milford, MA, USA.
+ Open protocol
+ Expand
3

Analytical Procedure for Chitin Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Petroleum ether (bp. 40 -60 °C, technical), H2SO4 (95 %, technical), K2SO4, CuSO4.5H2O, NaOH, and H3BO3 were all supplied by VWR Chemicals. Tin pressed capsules (8 mm 𝗑 5 mm, standard clean) and all reagents required for the Dumas method were purchased from OEA Laboratories Ltd. Helium was supplied by Nippon Gases. The analytical standard of acetanilide was provided by Thermo Fisher. Chitin (practical grade), HCl (37.0 %), 9-fluorenylmethyl chloroformate (FMOC-Cl), D-glucosamine hydrochloride (analytical standard), and amino acid standards were purchased from Sigma Aldrich. Syringe filters (Chromafil PET 0.20 µm) and Soxhlet thimbles were supplied by Macherey-Nagel. ULC-MS grade acetonitrile and formic acid were bought from Biosolve. The derivatisation reagent for amino acid analyses (6aminoquinolyl-N-hydroxysuccinimidyl carbamate, AQC) was supplied by Waters Co.
Ultrapure water was obtained through the Arium Pro® UV from Sartorius. All reagents were of analytical grade unless specified otherwise.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!