The largest database of trusted experimental protocols

Florisil cartridges

Manufactured by Merck Group
Sourced in Belgium, United States

Florisil® cartridges are a type of solid-phase extraction (SPE) sorbent used for sample cleanup and analyte enrichment in various analytical techniques. They are composed of a chemically modified silica material that selectively retains specific analytes while allowing interfering compounds to pass through. Florisil® cartridges are typically used for the purification and concentration of organic compounds from complex matrices, but their detailed usage and application recommendations should be obtained from the manufacturer or product literature.

Automatically generated - may contain errors

2 protocols using florisil cartridges

1

Analytical Standards for Brominated Flame Retardants

Check if the same lab product or an alternative is used in the 5 most similar protocols
Standards of BDE-28, -49, -47, -99, -100, -153, -154, -138, -183, and -209, 1,2-Bis(2,4,6tribromophenoxy)ethane (BTBPE), syn-DP and anti-DP isomers, 2-ethylhexyl-2,3,4,5 tetrabromobenzoate (TBB), 2,3,4,5-tetrabromophthalate (TBPH), hexabromobenzene (HBB), dechlorane-602 (Dec-602), dechlorane-603 (Dec-603), isotopically labelled internal standards (IS) 13 C-BDE-209, 13 C-TBPH, 13 C-TBB, 13 C-syn-DP, and 13 C-anti-DP were purchased from Wellington Laboratories (Guelph, ON, Canada). Recovery standard (RS) CB-207 was purchased from Dr. Ehrenstorfer Laboratories (Augsburg, Germany). Polypropylene (PP) tubes (15 mL) were obtained from Greiner Bio-one (Belgium). Empty PP cartridges (25 mL) were purchased from Grace (Lokeren, Belgium), while Florisil® cartridges (500 mg, 3 mL) and empty PP cartridges (6 mL) were purchased from Supelco (Bellefonte, PA, USA). Silica gel, anhydrous sodium sulphate (Na 2 SO 4 ) and concentrated sulfuric acid (H 2 SO 4 , 98%) were purchased from Merck (Darmstadt, Germany). All solvents were of chromatography grade: n-hexane was purchased from Acros Organics (Belgium); dichloromethane (DCM), iso-octane, toluene and acetonitrile (ACN) were purchased from Merck.
+ Open protocol
+ Expand
2

Analytical Method for Flame Retardants

Check if the same lab product or an alternative is used in the 5 most similar protocols
Standards of TCEP, TDCIPP, TEHP, EHDPHP, TCIPP (mixture of 2 isomers), and TPHP were purchased from Chiron AS (Trondheim, Norway). Triamyl phosphate (TAP) (IS) was purchased from TCI Europe (Zwijndrecht, Belgium). Labeled internal standards, TPHP-d15, TDCIPP-d15, TBOEP-d6, and TCEP-d12 (IS) were custom synthesized. Recovery standard (RS) chlorobiphenyl CB-207 was purchased from Dr. Ehrenstorfer Laboratories (Augsburg, Germany). Polypropylene syringes were purchased by Sigma-Aldrich (St. Louis, MO, USA). QuE Z-Sep sorbent powder and Florisil ® cartridges (500 mg, 3 mL) were purchased from Supelco (Bellefonte, PA, USA). All solvents were chromatography grade: n-hexane (n-Hex) was purchased from Acros Organics (Belgium); ethyl acetate (ETAC), dichloromethane (DCM), iso-octane, and acetonitrile (ACN) were purchased from Merck (Darmstadt, Germany). All chemicals were analytical reagent grade or equivalent analytical purity.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!