6120 quadrupole hplc ms system

Manufactured by Agilent Technologies
Sourced in United States

The 6120 Quadrupole HPLC/MS system is a liquid chromatography-mass spectrometry (LC/MS) instrument designed for analytical applications. It combines high-performance liquid chromatography (HPLC) with a quadrupole mass spectrometer to enable the separation, identification, and quantification of chemical compounds in complex samples.

Automatically generated - may contain errors

2 protocols using 6120 quadrupole hplc ms system

1

Analytical Techniques for Natural Product Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were measured on a P2010 polarimeter (JASCO Inc, Easton, MD, USA). Low-resolution electrospray ionization (ESI) mass spectra were measured on a 6120 Quadrupole HPLC/MS system (Agilent, Santa Clara, CA, USA) equipped with a Kinetex C18 (2) 5 μm column (4.6 mm × 250 mm, Phenomenex, Torrance, CA, USA). High-resolution ESI-MS data were obtained using an Agilent iFunnel 6550 Q-TOF (quadrupole time-of-flight) MS instrument. NMR spectra including 2D-NMR (gCOSY, gHSQC, and gHMBC) were recorded on an Agilent 600 MHz NMR spectrometer equipped with a cold probe. Chemical shifts were referenced to residual solvents. A Sep-Pak® Vac 35cc (10 g) C18 cartridge (Waters, Milford, MA, USA) was used for flash column chromatography. The separation of crude extracts was performed on an Agilent Prepstar HPLC system using an Agilent Polaris C18-A 5 μm (21.2 mm × 250 mm) column and a Phenomenex Luna C18 or C8 (2) 10 μm column (10.0 mm × 250 mm).
+ Open protocol
+ Expand
2

Analytical Techniques for Natural Product Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were measured on a P2010 polarimeter (JASCO Inc, Easton, MD, USA). Low-resolution electrospray ionization (ESI) mass spectra were measured on a 6120 Quadrupole HPLC/MS system (Agilent, Santa Clara, CA, USA) equipped with a Kinetex C18 (2) 5 μm column (4.6 mm × 250 mm, Phenomenex, Torrance, CA, USA). High-resolution ESI-MS data were obtained using an Agilent iFunnel 6550 Q-TOF (quadrupole time-of-flight) MS instrument. NMR spectra including 2D-NMR (gCOSY, gHSQC, and gHMBC) were recorded on an Agilent 600 MHz NMR spectrometer equipped with a cold probe. Chemical shifts were referenced to residual solvents. A Sep-Pak® Vac 35cc (10 g) C18 cartridge (Waters, Milford, MA, USA) was used for flash column chromatography. The separation of crude extracts was performed on an Agilent Prepstar HPLC system using an Agilent Polaris C18-A 5 μm (21.2 mm × 250 mm) column and a Phenomenex Luna C18 or C8 (2) 10 μm column (10.0 mm × 250 mm).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!