The largest database of trusted experimental protocols

Hd truex

Manufactured by Siemens

The HD; TrueX is a laboratory equipment product from Siemens. It is designed to perform specific functions within a laboratory setting. The core function of this product is to provide high-quality data and reliable performance for laboratory applications.

Automatically generated - may contain errors

2 protocols using hd truex

1

Whole-Body and Breast PET Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
PET imaging studies were performed on a Biograph TrueV (Siemens Medical Solutions). 18F-FDG injection was preceded by a 6-h fasting period and a 15-min rest in a warm room. Patients were scanned 60 min after 18F-FDG injection from the skull base to the mid-thighs (2 min 40 s per bed position for normal-weight patients (BMI ≤ 25 kg/m2) and 3 min and 40 s per bed position for patients with BMI > 25 kg/m2). Images were reconstructed using a point spread function (PSF) algorithm (HD; TrueX, Siemens Medical Solutions, 3 iterations and 21 subsets) with no post-filtering (PSFWholeBody) and a 1682 matrix size leading to a voxel size of 4.1 × 4.1 × 5.0 mm. A complementary high-resolution (HR) breast dedicated bed position (6 min per bed position) was performed just after the completion of the skull base to the mid-thighs acquisition. Images were reconstructed using the same protocol as above (PSFbreast) and an ordered subset expectation maximization (OSEM) algorithm (four iterations, eight subsets) with a Gaussian post-filtering of 5 mm (OSEMbreast) with a 5122 matrix size leading to voxels of 1.3 × 1.3 × 1.9 mm. Scatter and attenuation corrections were applied for both acquisitions.
+ Open protocol
+ Expand
2

18F-Choline PET/CT Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
As previously described (3 (link)), 18FCH PET/CT images were acquired on a Biograph 6 TrueV PET/CT system (Siemens Medical Solutions, Erlangen, Germany) with an extended field-of-view of 21.6 cm. A PET acquisition of 10 min (one-bed position) covering the neck and upper chest was performed in 3D list-mode 20 and 60 min after intravenous injection of 1.5 MBq/kg of 18FCH. For each acquisition, a low-dose CT (CAREdose ref. mAs 100, 130 kV, slice 3 mm, pitch 1.0) was performed. For clinical interpretation, PET raw data at 20 and 60 min were reconstructed with the point spread function (PSF) reconstruction algorithm (HD; TrueX, Siemens Medical Solutions; 3 iterations and 21 subsets) without filtering, with matrix size 256 × 256 and zoom 1.0. Scatter and attenuation corrections were applied. To fulfill EARL guideline requirements (9 (link)), an EARL1 reconstruction was generated with the same parameters and a postfiltering Gaussian filter of 6 mm was applied.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!