Thermo nicolet avatar 370 ftir spectrometer

Manufactured by Thermo Fisher Scientific
Sourced in United States

The Thermo Nicolet Avatar 370 FTIR spectrometer is a laboratory instrument designed for the analysis of various materials and samples. It utilizes Fourier Transform Infrared (FTIR) technology to provide precise and accurate spectroscopic measurements. The core function of this spectrometer is to collect infrared absorption data, which can be used to identify and characterize the chemical composition of a wide range of substances.

Automatically generated - may contain errors

4 protocols using thermo nicolet avatar 370 ftir spectrometer

1

Comprehensive Characterization of Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
SEM (Shimadzu, Co. Ltd., Kyoto, Japan) was carried out on a Shimadzu SSX-550 field emission scanning electron microscope. A drop of the sample suspended in ethanol was placed on a piece of silicon wafer. After 10 min of air-drying, a thin gold coating was applied to prevent charging during scanning, then a thorough microscopic study was carried out. EDX spectroscopy was also used during the SEM measurements to examine the elemental composition of the samples. The detailed morphology, size, and inner state of the samples were surveyed using a Hitachi H-8100 transmission electron microscope (Hitachi, Ltd., Tokyo, Japan). For TEM imaging, the samples were suspended in ethanol with the assistance of sonication at 35 KHz, and the as-prepared suspensions were added onto a copper grid and air-dried at room temperature. FTIR spectrometry was performed on a Thermo Nicolet Avatar 370 FTIR spectrometer (Thermo Fisher Scientific Co. Ltd., Waltham, MA, USA). XPS was run on a PHI-5000CESCA system with Mg Kα radiation. The active chlorine content was quantified using an iodometric/thiosulfate assay.
+ Open protocol
+ Expand
2

Comprehensive Characterization of Nanomaterials

Check if the same lab product or an alternative is used in the 5 most similar protocols
1H-NMR spectra were recorded on a Bruker AVANCE III-500 instrument (Bruker, Co. Ltd., Billeria, MA, USA) in D2O solution. Fourier transform infrared (FTIR) spectrometry was recorded on a Thermo Nicolet Avatar 370 FTIR spectrometer (Thermo Fisher Scientific Co. Ltd., Waltham, MA, USA). X-ray photoelectron spectroscopy (XPS) was carried out on a PHI-5000CESCA system with Mg K radiation. Scanning electron microscopy (SEM) images (Shimadzu, Co. Ltd., Kyoto, Japan) were taken on a Shimadzu SSX-550 field emission scanning electron microscope at 15.0 kV. A drop of the well-dispersed sample in ethanol was cast onto a piece of silicon wafer and air dried. A thin gold coating was utilized to avoid charging during scanning, and a thorough microscopic study was carried out. Energy-dispersive X-ray (EDX) spectroscopy was also performed during the SEM measurements. The detailed morphology and size of the samples were observed with a Hitachi H-8100 transmission electron microscope (TEM, Hitachi, Ltd., Tokyo, Japan). The samples were well dispersed in ethanol with the assistance of sonication at 35 KHz, and the as-prepared dispersion was added dropwise onto the copper grid and dried at room temperature for TEM characterization.
+ Open protocol
+ Expand
3

Spectroscopic Analysis of Coumarin Derivatives

Check if the same lab product or an alternative is used in the 5 most similar protocols
The IR spectra of investigated coumarin derivatives were recorded on a Thermo Nicolet-Avatar 370 FTIR spectrometer (Thermo Fisher, Waltham, MA, USA) in the range between 4000 and 400 cm−1. The samples were prepared in the KBr pallet with the mass ratio of derivatives: KBr = 2 mg: 150 mg. The UV-VIS spectra were obtained in ethanol on the Thermo Scientific–Evolution 220 spectrophotometer (Thermo Fisher, Waltham, MA, USA) between 800 and 200 nm. The NMR spectra were measured on a Bruker AvanceTM 400 MHz spectrometer (Bruker, Billerica, MA, USA). Chemical shifts are shown relative to TMS.
+ Open protocol
+ Expand
4

NMR and IR Spectroscopy Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
NMR spectra were measured on a Bruker AvanceTM 400 MHz Spectrometer (1H, 400.13 MHz; 13C, 100.50 MHz). Chemical shifts (δ) are given in parts per million (ppm) and coupling constants (J) in hertz (Hz). Referencing was done to internal tetramethylsilane or respective undeuterated solvent residue signals. The infrared spectra were recorded on a Thermo Nicolet—Avatar 370 FTIR spectrometer, Thermo Fisher, Waltham, MA, USA in the range between 4000 and 400 cm−1. The KBr pellet technique was used with the mass ratio 1: KBr = 4 mg:150 mg.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!