The largest database of trusted experimental protocols

Mass frontier software v 6.0

Manufactured by Thermo Fisher Scientific

Mass Frontier software (v. 6.0) is a data analysis tool designed for mass spectrometry applications. The software provides features for processing and interpreting mass spectrometry data.

Automatically generated - may contain errors

2 protocols using mass frontier software v 6.0

1

Serum Metabolic Fingerprinting by HRMS

Check if the same lab product or an alternative is used in the 5 most similar protocols
Starting from 20 μl of serum samples, prepared according to the method of Melo et al. (46 (link), 47 (link)), patients and control groups were evaluated in quintuplicates through direct injection into a high-resolution mass spectrometer (HRMS; ESI-LTQ-XL Orbitrap Discovery instrument [Thermo Scientific, Bremen, Germany]). Instrumentation parameters were set as follows: sample flow of 10 μl/min, sheath gas at 10 arbitrary units, source voltage of 5 kV, and capillary temperature of 280°C. Analytical quintuplicates were prepared and analyzed for each sample, from which metabolic fingerprints were captured in the mass range of 750 to 1,700 m/z in the positive ion mode.
Intending to confirm our findings, tandem mass spectrometry (MS/MS) was applied in the same instrument mentioned above. The collision gas used was helium, with collision-induced dissociation energy ranging from 30 to 60 (arbitrary units). The obtained experimental mass fragmentation spectra were collected and compared to in silico mass fragmentation profiles of each marker, simulated with Mass Frontier software (v. 6.0; Thermo Scientific, San Jose, CA).
+ Open protocol
+ Expand
2

Metabolite Identification Workflow

Check if the same lab product or an alternative is used in the 5 most similar protocols
Human Metabolome database version 3.6 (www.hmdb.ca), LipidMaps (www.lipidmaps.org), and METLIN (Scripps Center for Metabolomics, La Jolla, CA) were consulted to elect the most suitable marker obtained from HRMS and mass accuracy; only molecules with a mass shift lower than 2 ppm were considered. Aiming to confirm the proposed molecules, Tandem mass spectrometry (MS/MS) data were acquired and structure proposals were carried out with the assistance of METLIN MS/MS databases and fragmentation calculations/ modeling predicted by Mass Frontier software (v. 6.0, Thermo Scientific, San Jose, CA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!