The largest database of trusted experimental protocols

3 protocols using dibenzoylmethane

1

Chitosan-based Fluorescent Sensor Synthesis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Chitosan (90% deacetylated), acetyl acetone, dibenzoyl methane, monochloroacetic acid, copper(ii) acetate monohydrate, 4-hydroxy benzohydrazide, methanol, acetic acid, methylene blue and sodium hydroxide were purchased from Sigma Aldrich and SRL India and used as supplied without further purification.
+ Open protocol
+ Expand
2

Heavy Metal Analysis in Environmental Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
The aluminum cans were obtained from commercial shops (Mansoura, Egypt). Isatoic anhydride, dibenzoylmethane, 4-amino-2-hydroxy benzoic acid, toluene, cadmium(ii) chloride, chloroacetyl chloride, nickel(ii) chloride hexahydrate, ethylenediaminetetraacetic acid tetrasodium salt dihydrate, zinc(ii) chloride, aluminum(iii) chloride hexahydrate, iron(iii) chloride hexahydrate, and lead(ii) chloride were obtained from Sigma-Aldrich. Hydrochloric acid, potassium chloride, sodium hydroxide, mercury(ii) chloride, and copper(ii) chloride dihydrate were purchased from Merck (Germany). The other chemicals were of analytical grade, obtained from Fluka (Switzerland) and were used without further purification unless otherwise stated. In addition, all aqueous solutions in this work were prepared by using doubly distilled water (resistance: 18.2 MΩ at 25 °C). It is worth mentioning that all glassware was rinsed in concentrated nitric acid solution (1% (v/v)) and washed with doubly distilled water before use. For analytical applications, the cucumber, lettuce leaves, and wastewater samples were collected from different agricultural locations in Samanoud (El-Gharbia).
+ Open protocol
+ Expand
3

Synthesis of Nanocrystal Materials

Check if the same lab product or an alternative is used in the 5 most similar protocols
Phenyl ether (99%), oleylamine (470%), oleic acid (90%), iron(III) acetylacetonate (99%), 1,2-fexadecanediol (90%), n-hexane (97%), cyclohexane (99.5%), Igepal s CO-520, tetraethylorthosilicate (TEOS, 499%), 2-thenoyltrifluoroacetone (99%), dibenzoylmethane (98%) ammonia solution (25-28 wt%), ethanol absolute (ACS grade), N,Ndimethylformamide -DMF (ACS grade), tetrahydrofuran -THF anhydrous, were purchased from Sigma Aldrich. The water used in all experiments was ultrapure. All other chemicals were used as received without further purification.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!