The lipid A sample was dissolved in chloroform/methanol (2:1, v/v) at a concentration of 10 µg/µl and one microliter of the sample was transferred into the target plate wells covered with a thin matrix film. The matrix solution was prepared from 2′,4′,6′-trihydroxyacetophenone (THAP) (200 mg/ml in methanol) mixed with nitrocellulose (NC) (15 mg/ml, suspended in 2-propanol/acetone (1:1, v/v)) in proportion of 4:1 (v/v), as previously described by Silipo et al. (2005 (link)).
Red phosphorous
Red phosphorus is a crystalline solid that is used in various laboratory applications. It serves as a chemical reagent and can be employed in the synthesis of organic compounds. Red phosphorus is also utilized as a desiccant and drying agent in certain laboratory procedures.
Lab products found in correlation
14 protocols using red phosphorous
MALDI-TOF–MS Analysis of Lipid A
The lipid A sample was dissolved in chloroform/methanol (2:1, v/v) at a concentration of 10 µg/µl and one microliter of the sample was transferred into the target plate wells covered with a thin matrix film. The matrix solution was prepared from 2′,4′,6′-trihydroxyacetophenone (THAP) (200 mg/ml in methanol) mixed with nitrocellulose (NC) (15 mg/ml, suspended in 2-propanol/acetone (1:1, v/v)) in proportion of 4:1 (v/v), as previously described by Silipo et al. (2005 (link)).
MALDI-TOF MS Analysis of LPS
MALDI-TOF and MS/MS Analysis of YGB
Tissue Preparation with Specialized Reagents
MALDI-TOF-MS Analysis of Phospholipids
MALDI-TOF-MS Characterization of Biomolecules
MALDI-TOF Mass Spectrometry of LPS and Oligosaccharides
Fabrication of PAN-based Coin Cells
MALDI-TOF Mass Spectrometry of Lipid A
MALDI-TOF MS Analysis of Lipid Extracts
All MALDI–TOF mass spectra were acquired on a Waters SYNAPT G2-Si HDMS instrument (Waters Corporation, Milford, MA, USA) equipped with a 1 kHz Nd:YAG laser system. Acquisition of the data was performed using MassLynx software version 4.1 SCN916 (Waters Corporation, Wilmslow, United Kingdom). Spectra were recorded in the positive ion polarities. For MS2 experiments, isolated precursor ions were fragmented using a collision voltage of 50–60 V. Data were collected for 120 s for each ion separately. Mass spectra were assigned with multipoint external calibration using red phosphorous (Sigma-Aldrich, St. Louis, MO, USA).
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!