The largest database of trusted experimental protocols

Epx precision microplate reader

Manufactured by Molecular Devices

The Epx Precision Microplate Reader is a compact and versatile instrument designed for high-performance absorbance measurements in microplates. It features a high-resolution optical system and a temperature-controlled incubator to ensure accurate and reliable data acquisition.

Automatically generated - may contain errors

2 protocols using epx precision microplate reader

1

Cytotoxicity Evaluation of AMB and ND-AMB

Check if the same lab product or an alternative is used in the 5 most similar protocols
To determine the cytotoxicity of cells after exposure to AMB or ND-AMB (18 h), culture medium was tested for the presence of released lactate dehydrogenase (LDH). A 96-well LDH Cytotoxicity Assay Kit (Cayman Chemical Company, Ann Arbor, MI) was used, with the following modifications: on the day of the assay, 100 μL of culture medium was removed and added to 100 μL of Reaction Solution. Absorbance at 490 nm was obtained with Epx Precision Microplate Reader (Molecular Devices, Sunnyvale, CA). We measured the LDH levels 30 min after exposure. Triton X-100 (10%) was used as a positive control (maximum release of LDH) and cell medium (without phenol) was used as a negative control (spontaneous release of LDH). % Cytotoxicity of test sample was calculated based on below formula: %Cytotoxicity=(Experimentalvalue)(Spontaneousrelease)(Maximumrelease)(Spontaneousrelease)×100
+ Open protocol
+ Expand
2

Ethanol-Induced Cell Cytotoxicity Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
To determine the cytotoxicity of cells after exposure to ethanol, culture medium was tested for the presence of released lactate dehydrogenase (LDH). A 96-well LDH Cytotoxicity Assay Kit (Abcam, Cambridge, MA) was used, with the following modifications: on the day of the assay, 50 μL of culture medium was removed and added to 50 μL of Substrate Mix. Absorbance at 450 nm was obtained with Epx Precision Microplate Reader (Molecular Devices, Sunnyvale, CA). We measured the LDH levels 30mins, 4, 8 and 24 hours after ethanol exposure at each dose (0.25%, 0.5% and 1%).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!