R 100 evaporator

Manufactured by Büchi
Sourced in Switzerland

The R-100 evaporator is a laboratory equipment designed for the efficient evaporation of solvents. It utilizes a rotary evaporation method to remove solvents from samples, concentrating the remaining material.

Automatically generated - may contain errors

2 protocols using r 100 evaporator

1

Analytical Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Commercially available reagents were used without further purification. Organic solvents were evaporated with reduced pressure using a Büchi R-100 evaporator (Büchi, Flawil, Switzerland). Reactions were monitored by TLC using Yantai JingYou (Yantai, China) GF254 silica gel plates. Silica gel column chromatography was performed on Biotage Isolera One (Biotage, Uppsala, Sweden). Melting points were measured by a Melting Point YRY-3 apparatus (Tianjin Precision Apparatus Factory, Tianjin, China). The purity of the samples was determined by an analytical Agilent 1260 HPLC (Agilent, Waldbronn, Germany) with ZDRBAX SB-C18 column (4.6 × 150 mm) using parameters as follows: H2O/MeOH, 40/60 to 0/100 in 15 min, plus 5 min isocratic MeOH, flow rate at 1.0 mL/min, λ = 254 and 280 nm. NMR spectra were measured on Bruker Avance III 600 MHz spectrometer (Bruker, Fällanden, Switzerland). Chemical shifts were expressed in δ (ppm) and coupling constants (J) in Hz with residual solvent signals as references (CDCl3, δH 7.26 ppm and δC 77.0 ppm; DMSO-d6, δH 2.50 ppm and δC 39.5 ppm). ESIMS (electrospray ionization mass spectrometry) analyses were performed on an Agilent 1260-6460 Triple Quard LC-MS instrument (Agilent, Waldbronn, Germany). HR-ESIMS data were acquired on an Agilent Q-TOF 6520 spectrometer (Agilent, Waldbronn, Germany).
+ Open protocol
+ Expand
2

Reagent Purification and Spectroscopic Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Commercially available reagents were used without further purification. Organic solvents were evaporated with reduced pressure using a Büchi R-100 evaporator (Büchi, Flawil, Switzerland). Reactions were monitored by TLC using Yantai Jingyou (Yantai, China) GF254 silica gel plates. Silica gel column chromatography was performed on Biotage Isolera One (Biotage, Uppsala, Sweden) using silica gel (200–300 mesh) from Qingdao Hailang (Qingdao, China). NMR spectra were measured on Bruker Avance III 600 MHz spectrometers (Bruker, Fällanden, Switzerland). Chemical shifts were expressed in δ (ppm) and coupling constants (J) in Hz with solvent signals as internal standards (CDCl3, δH 7.26 ppm and δC 77.0 ppm; DMSO-d6, δH 2.50 ppm and δC 39.5 ppm). ESI-MS (electrospray ionization mass spectrometry) analyses were performed on an Agilent 1260–6460 Triple Quard LC-MS instrument (Agilent, Waldbronn, Germany), and HR-ESIMS data were acquired on an Agilent Q-TOF 6520 (Agilent, Waldbronn, Germany).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!