Ettan daltsix vertical system

Manufactured by GE Healthcare
Sourced in United States

The Ettan DALTsix Vertical System is a laboratory equipment designed for performing 2D gel electrophoresis. It provides a platform for separating complex protein mixtures based on their isoelectric point and molecular weight. The system includes components necessary for the electrophoresis process, such as glass plates, spacers, and a vertical electrophoresis tank.

Automatically generated - may contain errors

4 protocols using ettan daltsix vertical system

1

Two-Dimensional Protein Electrophoresis Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Protein (1mg) was subjected to IEF using an IPGphor III system (Gelifescience, Xiamen, China) with 24 cm IPG strips (Immobiline Drystrip™, pH 4–7) and then resolved on a 12.5% slab gel with SDS- PAGEl. The gel was overlaid with 0.5% agarose (dissolved in running buffer containing bromophenol blue) and 2-DE was run using an Ettan DALTsix Vertical System (Gelifescience, USA) at 1 W/gel for 30 min, and then at 15 W/gel until the dye front reached the bottom of the gel. IEF was carried out as Wang ( 11 (link)
).
+ Open protocol
+ Expand
2

High-Resolution 2-DE Proteomic Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
High-resolution 2-DE was performed according to Görg et al. [43 (link)] with some modifications as previously described by Franco et al. [41 (link)]. The first dimension was run in 24 cm long pH 4–7 linear gradient ReadyStripTM IPG Strips (Bio-Rad Laboratories, Hercules, CA, USA), loaded with 450 µg of protein from each sample, concurrently with 0.6% DTT and 1% immobilized pH gradient (IPG) buffer (Bio-Rad Laboratories). Isoelectric focusing (IEF) was performed on PROTEAN IEF Cell (Bio-Rad Laboratories). Initially, 50 V were applied for 12 h to rehydrate each strip, following a voltage grade until 70 kWh. Subsequently, strips were immersed in equilibration buffer I (50 mM Tris pH 8.8, 30% glycerol, 2% SDS, 6 M urea and 1% DTT) for 15 min at room temperature and in the same conditions with equilibration buffer II (50 mM Tris pH 8.8, 30% glycerol, 2% SDS, 6 M urea and 2.5% iodoacetamide). For the second dimension, proteins were resolved on 13% SDS-PAGE gels of 24 × 20 cm using Ettan DALTsix vertical system (GE Healthcare).
+ Open protocol
+ Expand
3

Two-Dimensional Gel Electrophoresis Proteomics

Check if the same lab product or an alternative is used in the 5 most similar protocols
One-dimensional analytical gel electrophoresis was performed, followed by two-dimensional sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) on 12.5% fixed concentration gels, as previously described [20 (link),21 (link),22 (link)]. Briefly, 1 mg from the pool was added to the rehydration buffer (7 M urea, 2 M thiourea, 4% CHAPS, 0.006 g DTT, 2 µL bromophenol blue, 5 µL IPG buffer (pI 3–11), a protease inhibitor cocktail) and applied to IPG strips. Isoelectric focusing was performed on an Ettan IPGphor IEF Unit (GE Healthcare, 30 V, 12 h, 20 °C at 50 µA per strip). Furthermore, the strips were treated by equilibration buffer with 0.1 g DDT and 0.9 g Iodoacetamide, respectively. Next, standard SDS-PAGE was preformed using an Ettan DALTsix Vertical System (GE Healthcare). The gels were scanned with a Sapphire biomolecular imager (Azure Biosystems, Dublin, OH, USA) and digitalized with Sapphire capture system image analysis software (Azure Biosystems, Dublin, OH, USA).
+ Open protocol
+ Expand
4

Quantitative Protein Analysis using 2D-PAGE

Check if the same lab product or an alternative is used in the 5 most similar protocols
Total protein extract (40 µg for silver staining or 500 µg for CBB G-250 staining) was used to rehydrate Immobiline DryStrip gels (pH 3-10 NL 18 cm; GE Healthcare). Proteins were resolved in the first dimension by isoelectric focusing for a total of 50 000 V-h by using the Ettan IPGphor 3 (GE Healthcare). After equilibration of the strips, the second dimension was performed on 8-16% polyacrylamide gradient gels (20 cm x 18 cm x 1 mm) and was run on an Ettan Daltsix vertical system (GE Healthcare). The 2D gels were silver-stained (PlusOne Silver Staining kit; GE Healthcare) for image analysis or dyed following the CBB G-250 staining method for mass spectrometric analysis. 28
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!