Avvance drx 400 nmr spectrometer

Manufactured by Bruker
Sourced in Switzerland

The AVVANCE DRX-400 NMR spectrometer is a nuclear magnetic resonance (NMR) instrument designed for analytical and research applications. It operates at a magnetic field strength of 9.4 Tesla, providing a proton frequency of 400 MHz. The spectrometer is capable of performing routine 1D and 2D NMR experiments for the analysis of various chemical compounds.

Automatically generated - may contain errors

3 protocols using avvance drx 400 nmr spectrometer

1

Synthesis and Characterization of TAT-Conjugated Polymer Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
The transactivating transcriptional activator (TAT) peptide (YGRKKRRQRRRC) with purity ≥97% was purchased from ChinaPeptides Co., Ltd. (Shanghai, China). Taxol injection was obtained from Yangtze River Pharmaceutical (Group) Co., Ltd. (Jiangsu, China). Hochest33342 and 4% paraformaldehyde were provided by Solarbio Science and Technology Co., Ltd. (Beijing, China). Acetonitrile for high-performance liquid chromatography (HPLC) was obtained from Tedia Company, Inc (Fairfeld, OH, USA). Anhydrous pyridine, 1-(2-Hydroxyethyl)-1H-pyrrole-2,5-dione (HEMI), PEG (Mw2000) and D, L-lactide were obtained from Aladdin Bio-Chem Technology Co., LTD (Shanghai, China). Dulbecco’s Modified Eagle Medium (DMEM) (high glucose) cell culture medium, penicillin/streptomycin stock solutions, fetal bovine serum (FBS) and Trypsin were all bought from Gibco BRL (Gaithersberg, MD, USA). Protonic nuclear magnetic resonance (1H-NMR) (400 MHz) was used to confirm the obtained compounds (Bruker AVVANCE DRX-400 NMR spectrometer, Bruker, Switzerland). In addition, gel permeation chromatography (GPC) (Waters 1515–2414, Waters, USA) was used to analyze all polymers by using tetrahydrofuran as the mobile phase (flow rate: 1 mL/min) at 30 °C. Polystyrene was used as standards.
+ Open protocol
+ Expand
2

Characterization of Copolymer Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
1H NMR spectra were recorded at 400 MHz (Bruker AVVANCE DRX-400 NMR spectrometer, Bruker, Switzerland). CDCl3 and DMSO-d6 were used as deuterated solvents. Chemical shifts (δ, ppm) were determined with internal solvent signal as reference (CHCl3: δ = 7.26, DMSO-d6: δ = 2.50). Monomer conversion during polymerization was determined based on the concentration of residual monomer using gas chromatography (GC) (FULI9720 series, RBX-5 capillary column 30 m × 0.32 mm × 1.0 μm). The column temperature was 150 °C (15 min). N2 was used as the eluent at a flow rate of 1.0 mL min−1. Gel permeation chromatography (GPC) (Waters 1515–2414, Waters, Milford, MA, USA) was used to determine the number- and weight-average molecular weights (Mn and Mw) and polydispersity (Mw/Mn) of copolymers in THF at 30 °C with 1 mL min−1 flow rate. Polystyrene standards were used to calibrate the instrument. Transmission electron microscopy (TEM) images were taken with a Hitachi HT7700 instrument operating at an accelerating voltage of 120 KV. The particle size and polydispersity index (PDI) of polymeric nanoparticles were determined by dynamic light scattering (DLS) equipped with a Malvern Nano ZS90 Zetasizer, a 632.8 nm He-Ne laser, and a 173° backscatter detector.
+ Open protocol
+ Expand
3

Polymer Characterization by NMR and GPC

Check if the same lab product or an alternative is used in the 5 most similar protocols
1H NMR spectra were recorded at 400 MHz (Bruker AVVANCE DRX-400 NMR spectrometer, Bruker, Switzerland). CDCl3 and DMSO-d6 were used as deuterated solvents. Chemical shifts (δ, ppm) were determined with internal solvent signal as reference (CHCl3: δ = 7.26, DMSO-d6: δ = 2.50). Gel permeation chromatography (GPC) (Waters 1515-2414, Waters, Milford, MA, USA) was used to determine the number- and weight-average molecular weights (Mn and Mw) and polydispersity (Mw/Mn) of copolymers in THF at 30 °C with 1 mL/min flow rate. Polystyrene standards were used to calibrate the instrument. Transmission electron microscopy (TEM) images were taken with a Hitachi HT7700 instrument operating at an accelerating voltage of 120 KV. The particle size and polydispersity index (PDI) of polymeric nanoparticles were determined by dynamic light scattering (DLS) equipped with a Malvern Nano ZS90 Zetasizer, a 632.8 nm He-Ne laser, and a 173° backscatter detector.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!