The largest database of trusted experimental protocols

Agilent masshunter quantitative analysis for qqq

Manufactured by Agilent Technologies

Agilent MassHunter Quantitative Analysis for QQQ is a software solution that enables quantitative analysis of data from Agilent's triple quadrupole mass spectrometry systems. The software provides tools for data processing, method development, and reporting.

Automatically generated - may contain errors

2 protocols using agilent masshunter quantitative analysis for qqq

1

Sperm Metabolite Extraction and LC-MS Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
After collection and washing, sperm pellets containing ten million purified sperm were treated with 700 ml of cold 40% acetonitrile, 40% methanol, and 20% water. Then samples were vortexed vigorously for 5 min at 4 °C and spun at 10,000g for 10 min at 4 °C. The supernatant was removed and placed in a SpeedVac until dry. To resuspend, 20 ml of methanol was added, followed by vortexing, and finally, 80 ml of water was added along with a final vigorous vortex. For LC–MS analysis, 4 ml of sample volume was injected. Analysis method was described previously (20 (link)). Briefly, cell metabolite extractions were analyzed with an Agilent 6470A triple quadrupole mass spectrometer, operating in negative mode, connected to an Agilent 1290 ultra-high-performance liquid chromatography (UHPLC) system (Agilent Technologies). The analytical column used was an Agilent ZORBAX RRHD Extend-C18 1.8 mm 2.1 × 150 mm coupled with a ZORBAX Extend Fast Guard column for ultra-high-performance liquid chromatography Extend-C18, 2.1 mm, 1.8 mm. The MassHunter Metabolomics dMRM database and method was used to scan for polar metabolites within each sample (Agilent Technologies). The resulting chromatograms were visualized in Agilent MassHunter Quantitative Analysis for QQQ (Agilent Technologies). The final peak areas were manually checked for consistent and proper integration.
+ Open protocol
+ Expand
2

Quantitative and Qualitative LC/MS Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
For data, recordings of Agilent MassHunter Workstation LC/MS Data Acquisition for 6400 Series Triple Quadrupole (Version 10.0 SR1) and Agilent MassHunter Optimizer (Version 10.0 SR1) were used. Quantitative analysis was done using Agilent MassHunter Quantitative Analysis for QQQ (Version 10.1).
For qualitative data evaluation, Agilent MassHunter Qualitative Analysis B.07.00 was used.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!