The largest database of trusted experimental protocols

Lumos 2 ft ir microscope

Manufactured by Bruker

The LUMOS II FT-IR microscope is a high-performance infrared imaging system designed for comprehensive sample analysis. It provides micro-FTIR spectroscopy capabilities with advanced imaging functions.

Automatically generated - may contain errors

Lab products found in correlation

3 protocols using lumos 2 ft ir microscope

1

Mapping Drug Distribution in ZIF-8 Matrices

Check if the same lab product or an alternative is used in the 5 most similar protocols
Drug distribution analysis was performed using a LUMOS II FT-IR microscope (Bruker). The imaging was performed in an area of 1000 × 1000 µm. The distribution of ZIF-8 was determined on the basis of the peaks area which occurs between 1486.3 and 1381.3 cm−1. The distribution of drug was determined on the basis of the P–O peak area which is characteristic of risedronate and occurs between 1177.7 and 982.1 cm−1. 60 scans were collected for each spectrum. The results were obtained in the reflectance mode. The results were processed using the OPUS 8 software (Bruker).
+ Open protocol
+ Expand
2

FT-IR Spectroscopy of Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
FT-IR spectroscopy was conducted using a Bruker Lumos II FT-IR microscope at Koptri Inc. (Seoul, Republic of Korea). The samples were scanned within a wavenumber range of 4000–400 cm−1 at a resolution of 4 cm−1, with a total of 32 scans per sample.
+ Open protocol
+ Expand
3

Chitin-EG Membrane Chemical Stability Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Samples of prepared membranes were immersed in 6 M KOH for 120 h. Assessment of chitin-EG membrane chemical stability was performed using a LUMOS II FT-IR microscope (Bruker). The material was tested in the ATR mode. The imaging was performed in an area of 1000 × 1000 µm. Stability was determined on the basis of the peak area which is characteristic of chitosan and occurs between 1700 and 1610 cm−1. 60 scans were collected for each spectrum. The results were processed using the OPUS software.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!