The largest database of trusted experimental protocols

Echopac software version 112

Manufactured by GE Healthcare
Sourced in Norway

EchoPAC Software version 112.0.0 is a software application developed by GE Healthcare for processing and analyzing echocardiographic data. The software provides tools for visualizing, measuring, and quantifying cardiac structures and functions based on acquired echocardiographic images and data.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using echopac software version 112

1

Echocardiographic Assessment of Atrial Function

Check if the same lab product or an alternative is used in the 5 most similar protocols
Transthoracic echocardiography was performed within 1 week before the procedure by a single experienced investigator by using an Epiq 7G (Phillips Academy, Andover, Massachusetts, USA) with a 2.5-MHz probe in the two-dimensional (2D), M, and Doppler modes. The routine evaluation consisted of the measurements of the heart chamber dimensions and the assessment of valvular function and myocardial contractility. The loops of transthoracic echocardiography were retrieved and analyzed for atrial function by one of the coauthors (UP) experienced in the echocardiography analysis, who was blinded for those general clinical data of the patients including BMI. Speckle-tracking imaging with the LA and RA strain analysis was performed by using EchoPAC Software version 112.0.0 (GE Healthcare, Horten, Norway). The five-wall model for LA segmentation corresponding with a six-segment division in apical two-chamber (2Ch) and four-chamber (4Ch) projections was used during the LA and RA strain analysis (18 (link)).
+ Open protocol
+ Expand
2

Echocardiographic Evaluation of Left Atrium

Check if the same lab product or an alternative is used in the 5 most similar protocols
Transthoracic echocardiography was performed 1 day before and 6 months after the procedure by a single experienced investigator using an Epiq 7G (Philips, Andover, MA, USA) with a 2.5-MHz probe in 2D, M, and Doppler modes. The routine check-up consisted of measurements of the heart chamber dimensions, the assessment of valvular function and myocardial contractility.
Transoesophageal echocardiography was performed in all of patient 24 h before the procedure to exclude the potential presence of an LA appendage thrombus.
Speckle-tracking imaging with LA strain analysis was performed using EchoPAC Software version 112.0.0 (GE Healthcare, Horten, Norway). The five-wall model for left atrium segmentation corresponding with a six-segment division in apical two- (2Ch) and four-chamber (4Ch) projections was used during the LA strain analysis [4 (link)].
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!