The largest database of trusted experimental protocols

Trio 3.0 tesla

Manufactured by Siemens

The Trio 3.0 Tesla is a high-performance magnetic resonance imaging (MRI) scanner developed by Siemens. It operates at a magnetic field strength of 3.0 Tesla, providing enhanced image quality and diagnostic capabilities compared to lower field strength systems. The Trio 3.0 Tesla is designed for use in clinical and research settings to capture detailed images of the human body.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using trio 3.0 tesla

1

Diffusion Tensor Imaging with 3T MRI

Check if the same lab product or an alternative is used in the 5 most similar protocols
Magnetic resonance imaging was performed with a Siemens Trio 3.0 Tesla magnetic resonance imaging system (Trio, Siemens Medical Systems) running version VA 24 software. Diffusion tensor imaging was performed using a single-shot echo-planar imaging pulse sequence. Imaging parameters were echo time=90 ms, repetition time=7200 ms, bandwidth of 1346 Hz/pixel, acquisition matrix of 128×64, field of view of 220 mm, and contiguous 3-mm slice thickness. All axial slices were acquired parallel to the anterior commissure-posterior commissure line. Images were acquired with diffusion weighting in each of 6 different directions, all with a b-value (diffusion weighting factor) of 1000. An image with no diffusion weighting (b-value of 0) was acquired as reference. The set of seven diffusion weighted images was acquired a total of 4 times for retrospective averaging to improve image quality, and then averaged together after the magnitude-image reconstruction.
+ Open protocol
+ Expand
2

Resting-State fMRI Study of Acupuncture

Check if the same lab product or an alternative is used in the 5 most similar protocols
The rs-fMRI data will be obtained with a Siemens TRio 3.0 Tesla MRI scanner in Beijing Hospital of Traditional Chinese Medicine. All rs-fMRI images will be taken from a contiguous echo planar imaging template under the following conditions: 33 axial slices, repetition time = 2000 ms, echo time = 30 ms, thickness/gap = 3.5/0.6 mm, field of view = 220 × 220 mm2, flip angle = 90°, and matrix size 64 mm × 64 mm with 240 volumes. All participants will receive the following instructions: stay awake, do not move, close your eyes, and do not try to think about anything. For an anatomic reference, T1 images will be obtained before resting state scans.
The real acupuncture and sham acupuncture groups will be examined three times (before treatment, after treatment, and in the follow-up period.) and the healthy controls will be examined only once.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!