The largest database of trusted experimental protocols

ε hexachlorocyclohexane

Manufactured by LGC
Sourced in Germany

ε-hexachlorocyclohexane is a chemical compound with the formula C₆H₆Cl₆. It is an isomer of the more commonly known insecticide lindane (γ-hexachlorocyclohexane). The core function of ε-hexachlorocyclohexane is as a chemical reagent for research and analytical purposes.

Automatically generated - may contain errors

3 protocols using ε hexachlorocyclohexane

1

Chlorodecane Standards Characterization Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
All the individual SCCP standards were purchased from Chiron, Norway and Dr. Ehrensforfer GmbH, Germany. The standards included 1,1,1,3,8,10,10,10-octachlorodecane (1,1,1,3,8,10,10,10-OctaCD), 1,1,1,3,10,11-hexachloroundecane (1,1,1,3,10,11-HexCU), 1,1,1,3,12,13-hexachlorotridecane (1,1,1,3,12,13-HexCT), 1,2,5,6,9-pentachlorodecane (1,2,5,6,9-PentaCD), 1,2,5,6,9,10-hexachlorodecane (1,2,5,6,9,10-HexCD), hexachlorodecane (1,2,4,5,9,10-HexCD), 1,2,4,5,6,9,10-heptachlorodecane (1,2,4,5,6,9,10-HepCD), 1,2,5,5,6,9,10-heptachlorodecane (1,2,5,5,6,9,10-HepCD), and 1,1,1,3,8,9-hexachlorononane (1,1,1,3,8,9-HexCN). Their concentrations and purities are listed in Table S1. The concentrations of chlorodecane standard solutions obtained from Ehrenstorfer GmbH have been adjusted according to the purity of the compounds as indicated. The injection internal standard, ε-hexachlorocyclohexane (ε-HCH, 10 mg∙L−1 in cyclohexane, 99.9%), and CP reference standards of SCCP mixtures (C10–13 with chlorine contents of 51.5, 55.5, and 63.0%) and MCCP mixtures (C14–17 with 42.0%, 52.0%, and 57.0% chlorine content) were purchased from Ehrenstorfer GmbH (Augsburg, Germany). 13C10-trans-Chlordane (100 mg∙L−1 in n-nonane, 99.9%) was obtained from Cambridge Isotope Laboratories (Andover, USA) and used as the surrogate standard. Other details are described in Text S1.
+ Open protocol
+ Expand
2

Analytical Standards for SCCPs

Check if the same lab product or an alternative is used in the 5 most similar protocols
The commercial standards of the SCCPs (chlorine contents of 51.5%, 55.5%, and 63.0%, with the congener group patterns shown in Fig. 1) at concentrations of 100 ng/μL in cyclohexane and ε-hexachlorocyclohexane (ε-HCH, solution in cyclohexane, 10 ng/μL) were purchased from Ehrenstorfer GmbH (Augsburg, Germany). The 13C10-trans-chlordane (100 ng/μL solution in n-nonane, purity 99%) was purchased from Cambridge Isotope Laboratories (Andover, USA). Pesticide-grade dichloromethane, n-hexane, acetone, cyclohexane, and toluene were purchased from JT Baker (Phillipsburg, NJ). Florisil (60–100 mesh) and silica gel (180–280 mesh) were purchased from Merck (Whitehouse Station, NJ). Anhydrous sodium sulfate was purchased from Sinopharm Chemical Reagent Beijing Co., Ltd.

Congener group pattern for commercial references of SCCPs (C10-13, 51.5%, 55.5% and 63.0% chlorine content).

Fig. 1
silica gel was activated at 550 °C for 12 h, Florisil was activated at 140 °C for 7 h, and Anhydrous sodium sulfate was activated at 660 °C for 6 h before use. A mixture of 30% (40%) acid silica gel was prepared by mixing 100 g of activated silica gel and 44 g (66 g) of concentrated sulfuric acid.
+ Open protocol
+ Expand
3

Chlorinated Persistent Organic Pollutant Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
1,2,5,6,9,10-Hexachlorodecane (1,2,5,6,9,10-hexCD, CP-4, 10 μg/mL in cyclohexane, 99.9%) and 13C-1,5,5,6,6,10-hexachlorodecane (13C-1,5,5,6,6,10-hexCD in cyclohexane, 100 ng/μL, >98%) were purchased from Cambridge Isotope Laboratories (Andover, USA). Standard stock solutions of MCCPs mixtures (C14–17 with chlorine contents of 42%, 52%, and 57%, 100 μg/mL in cyclohexane) and the injection standard of ε-hexachlorocyclohexane (ε-HCH in cyclohexane, 10 ng/μL, 99.9%) were obtained from Dr. Ehrenstorfer GmbH (Augsburg, Germany). HPLC-grade methanol and acetone were purchased from Fisher chemical (Waltham, MA). Ultra resi-analyzed ethyl acetate, pesticide-grade dichloromethane, n-hexane, and cyclohexane were obtained from J.T. Baker (Phillipsburg, NJ). Supelclean LC-Florisil SPE Tubes (1 g, volume 6 mL) were bought from Supelco (Sigma-Aldrich, St. Louis, MO). HLB 6 cm3 (200 mg) columns were purchased from Waters (Milford, MA). Ultrapure water (18.2 MΩ·cm) was prepared with a milli-Q purification system (Millipore, Billerica, MA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!