The largest database of trusted experimental protocols

C18 0

Manufactured by Merck Group

C18:0 is a type of fatty acid that is commonly used in laboratory equipment. It serves as a core component in various analytical and purification processes. The detailed technical specifications and intended applications of this product are not readily available from our marketing materials.

Automatically generated - may contain errors

3 protocols using c18 0

1

Fatty Acid Determination Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Chloroform, ethyl alcohol (96% w/w), methanol, n-hexane, formic acid (99% w/w) hydrochloric acid (37% w/w) and anhydrous sodium sulphate were of analytical grade and were purchased from Carlo Erba (Milan, Italy). Boron trifluoride (approximately 10% w/w in methanol for gas chromatography (GC) derivatization) was purchased from Sigma-Aldrich (St. Louis, MO, USA). Fatty acid standards (C16:0, C16:1, C17:0, C18:0, C18:1, C18:2, C18:3) were also purchased from Sigma-Aldrich.
+ Open protocol
+ Expand
2

Lipid Profiling Using FTICR-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
Lipid profiling was performed using a 9.4 T Apex-ultraTM hybrid Qh-FTICR mass spectrometer (Bruker Daltonics, Billerica, MA, USA) equipped with a 200 Hz, 355 nm Nd:YAG laser. In positive ion mode, Instrument calibration was performed using a phospholipid mixture (PC 24:0 at m/z 622.44423, PC 32:0 at m/z 734.56943, PC 36:0 at m/z 790.63203, and PC 44:2 at m/z 898.72593 from Avanti Polar Lipids, Inc.), and mass spectra were obtained over the m/z range of 500 ~1000. Three commercially available standard FAs (C16:0 at m/z 255.23296, C18:0 at m/z 283.26425, and C22:6 at m/z 327.23294 from Sigma-Aldrich) with the ESI Tuning Mix (Part No. G2432A, Agilent Technology, Inc.) were used for instrument calibration over the m/z range of 100~1000 in negative ion mode. For data acquisition, a mass spectrum was accumulated in broadband mode by three full scans once with 100 laser shots using 1Mb data points over the above-mentioned ranges in the positive and negative ion modes, respectively. Ten mass spectra were randomly collected over a whole slide. All spectra were acquired using ApexControl 3.0.0 (Bruker Daltonics).
+ Open protocol
+ Expand
3

Hybrid FTICR-MS Lipid Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
All experiments were performed using a 9.4 T Apex-ultraTM hybrid Qh-FTICR MS (Bruker Daltonics, Billerica, MA, USA) equipped with a 200 Hz, 355 nm Nd: YAG laser. All spectra were acquired using ApexControl 3.0.0 (Bruker Daltonics). A lipid mixture (PC(24:0) at m/z 622.44423, PC(32:0) at m/z 734.56943, PC(36:0) at m/z 790.63203, and PC(44:2) at m/z 898.72593 from Avanti Polar Lipids, Inc.) was used to calibrate the instrument over the m/z range of 600 ~ 1000 in the positive ion mode and a FA mixture of three commercially-available standard (C16:0 at m/z 255.23296, C18:0 at m/z 283.26425, and C22:0 at m/z 339.32684 from Sigma-Aldrich) combined with the ESI Tuning Mix (Part No. G2432A, Agilent Technology, Inc.) was used to calibrate the instrument over the m/z range of 100 ~ 1000 in the negative ion mode. For membrane lipid profiling, a mass spectrum was accumulated with three full scans once with 100 laser shots in the positive and negative ion modes, respectively. For each slide, eight mass spectra were randomly collected.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!