The largest database of trusted experimental protocols

Magnetom 3t allegra mri system

Manufactured by Siemens
Sourced in Germany

The Magnetom 3T Allegra MRI system is a magnetic resonance imaging (MRI) scanner designed and manufactured by Siemens. It operates at a magnetic field strength of 3 Tesla, which enables high-resolution imaging and enhanced diagnostic capabilities. The system is capable of performing a wide range of MRI examinations, including neurological, musculoskeletal, and body imaging, to assist healthcare professionals in their clinical practice.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using magnetom 3t allegra mri system

1

Diffusion-weighted MRI with head coil optimization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Diffusion weighted images were acquired on a Siemens Magnetom 3T Allegra MRI system (Allegra MR2004A, Germany) with an RF transmit/receive head coil using a spin-echo, echo-planar sequence and including 45 non-collinear directions. To overcome limitations with scanning smaller volumes of tissue, voltage was reduced to optimise signal and the head coil was loaded with a wet clay inlay (40×40 cm with a thickness of 2 cm, standard sculpting clay commercially bought – white stoneware clay with grog). Images were obtained in the transverse plane with both anterior–posterior and posterior–anterior phase encoding to control for anatomic distortions and increase signal-to-noise. Parameters were as follows: repetition time (TR) 7900 ms; echo time (TE) 90 ms; slice thickness 1.6 mm; held of view 160 mm; voxel size 1.3 × 1.3 × 1.6 mm3; b-values 0 and 1000 s/mm2. Scan time per phase encoding acquisition was 6:27 min with a total time of 12 : 54 min for both acquisitions.
+ Open protocol
+ Expand
2

Optimized 3T MRI Brain Imaging

Check if the same lab product or an alternative is used in the 5 most similar protocols
Magnetic resonance imaging (MRI) was acquired at the Cape Universities Brain Imaging Centre (CUBIC), Tygerberg, Cape Town. Images were acquired on a Siemens Magnetom 3T Allegra MRI system (Erlangen, Germany) with a RF transmit/receive head coil. To overcome limitations with scanning smaller volumes of tissue, voltage was reduced to optimize signal, and the head coil was loaded with a wet clay inlay (40×40 cm with a thickness of 2 cm, standard sculpting clay commercially bought – white stoneware clay with grog).
A 3D T2 image was acquired on the 3T Siemens Allegra in the sagittal direction with the following parameters: FOV = 160×160 mm, TR = 3500 ms, TE = 354 ms, 128 slices, in-plane resolution = 1.3×1.3 mm and a slice thickness of 1.0 mm. The sequence scan time was 5 min 41 s.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!