Thirty two channel head coil

Manufactured by Siemens
Sourced in Germany

The thirty-two-channel head coil is a specialized piece of lab equipment used for magnetic resonance imaging (MRI) procedures. It is designed to be placed around the head of a patient or research subject to capture high-quality images of the brain and surrounding areas.

Automatically generated - may contain errors

3 protocols using thirty two channel head coil

1

Multiband Accelerated fMRI Acquisition

Check if the same lab product or an alternative is used in the 5 most similar protocols
A Siemens Magnetom Trio 3T whole body MRI scanner and a thirty-two-channel head coil were used. Multi-band accelerated echo planar imaging sequencing (Center for Magnetic Resonance Research, Minnesota) was used with an acceleration factor of 6 and iPAT acceleration factor of 2. T2*-weighted EPI slices were obtained every 0.7 s (TR = 0.7, TE = 0.03), these parameters were optimised given our scanner capability and used to increase sampling rates and increase our power to detect resting state networks as has been shown previously with multiband (Xu et al., 2013 (link), Filippini et al., 2014 (link)). 54 transverse slices with in-plane resolution of 2.4 × 2.4 mm were attained and slice thickness was 2.4 mm. The matrix size was 96 × 96 and the field of view (FOV) were 230 × 230 mm. Acquisition was performed during resting-state scan, yielding 400 vol in total. Sagittal 3D MPRAGE images were also acquired with an isotropic in-plane resolution of 1 × 1 × 1 (TI = 0.9 s, TR = 2.02, flip angle 9°, FOV = 250 × 250 mm) yielding 192 slices.
+ Open protocol
+ Expand
2

Structural MRI Acquisition and Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
MRI scans were collected at the University of California-Davis Imaging Research Center on a 3T Siemens (Erlangen, Germany) Trio equipped with a thirty-two-channel head coil. Structural T1-weighted images were acquired using a three-dimensional MPRAGE pulse sequence with voxel size 1x1x1 mm. High-resolution structural images were acquired using a T2-weighted turbo-spin echo sequence voxel size = 0.4 x 0.4 x 1.9 mm (see Ekstrom et al, 2009 ). Medial temporal lobe volumes normalized by total intracranial volume were estimated with SIENAX (Smith et al., 2002 (link)), part of FSL (Smith et al., 2004 (link)).
+ Open protocol
+ Expand
3

Functional MRI Acquisition Protocol for Neuroimaging

Check if the same lab product or an alternative is used in the 5 most similar protocols
The experimental protocol consisted of an event-related interleaved design. A Siemens Magnetom Trio 3T whole body MRI scanner and a thirty-two-channel head coil were used. Multi-band accelerated pulse sequencing (Version number RO12 Center for Magnetic Resonance Research, University of Minnesota, EPI 2D BOLD/SE/DIFF Sequence) was used with an acceleration factor of 6. T2*-weighted echo planner imaging slices were obtained every 0.7 seconds (TR). Imaging parameters were chosen to reduce distortion artefact in the orbitofrontal cortex (Wilson et al., 2002) . 54 Axial slices with in-plane resolution of 2.4 x 2.4mm and between plane spacing of 2.4mm were attained. The matrix size was 96 x 96 and the field of view were 230 x 230mm. Acquisition was performed during task performance, yielding approximately 3500 volumes. An anatomical T1 volume with sagittal plane slice thickness 1mm and in-plane resolution of 1.0 × 1.0 mm was also acquired.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.