The largest database of trusted experimental protocols

Leo912ab 120 kv transmission electron microscope

Manufactured by Zeiss
Sourced in Germany

The Zeiss LEO912AB is a 120 kV transmission electron microscope. Its core function is to produce high-resolution images and analysis of small-scale structures by transmitting a beam of electrons through a thin specimen.

Automatically generated - may contain errors

2 protocols using leo912ab 120 kv transmission electron microscope

1

Electron Microscopy Sample Preparation

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cells were pelleted via centrifugation, and the cell pellet was fixed in 2.5% glutaraldehyde in 0.1 M phosphate buffer (pH 7.4) at 4 °C. After 2 h, the pellet was rinsed three times in 0.1 M phosphate buffer and then post-fixed in 1% osmium tetroxide at 4 °C for 1–2 h, followed by three washes in phosphate buffer. The pellet was dehydrated via a series of ethanol solutions and exposed to two changes of propylene oxide. After the dehydration process, the pellet was infiltrated with 2:1, 1:1, and 1:2 mixtures of EMbed 812 resin and propylene oxide for 1 h each time and then finally embedded in 100% EMbed 812 resin. After polymerization for 24–48 h at 60 °C, ultrathin plastic sections (80-nm thick) were cut at room temperature using a Leica EM UC6 ultramicrotome (Leica Microsystems GmbH, Wetzlar, Germany) and collected on 200-mesh carbon-coated grids. The grids were post-stained with 2% uranyl acetate and 1% lead citrate at room temperature for 15 and 5 min, respectively. The Zeiss LEO912AB 120 kV transmission electron microscope (Carl Zeiss, Oberkochen, Germany) and FEI Tecnai G2 Spirit Twin 120 kV transmission electron microscope (FEI Company, Columbia, MD, USA) were used for transmission electron microscopy observations.
+ Open protocol
+ Expand
2

Transmission Electron Microscopy Sample Preparation

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cells were pelleted via centrifugation and fixed in 2.5% glutaraldehyde in 0.1 M phosphate buffer (pH 7.4) at 4°C. After 2 h, the pellets were rinsed three times in 0.1 M phosphate buffer and then postfixed in 1% osmium tetroxide at 4°C for 1–2 h, followed by three washes in phosphate buffer. The pellets were dehydrated through a series of ethanol solutions and exposed to two changes of propylene oxide. After the dehydration process, the pellets were infiltrated with 2 : 1, 1 : 1, and 1 : 2 mixtures of EMbed 812 resin and propylene oxide for 1 h each time. They were finally embedded in 100% EMbed 812 resin. After the resin had been polymerized for 24–48 h at 60°C, ultrathin plastic sections (80 nm thick) were cut at room temperature using a Leica EM UC6 ultramicrotome (Leica Microsystems GmbH, Wetzlar, Germany) and collected on 200-mesh carbon-coated grids. The grids were poststained with 2% uranyl acetate and 1% lead citrate at room temperature for 15 and 5 min, respectively. A Zeiss LEO912AB 120 kV transmission electron microscope (Carl Zeiss, Oberkochen, Germany) and a FEI Tecnai G2 Spirit Twin 120 kV transmission electron microscope (FEI Company, Columbia, MD, USA) were used for transmission electron microscopy observations.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!