The largest database of trusted experimental protocols

Sc 13118 fitc

Manufactured by Miltenyi Biotec

The Sc-13118 FITC is a fluorescent antibody reagent manufactured by Miltenyi Biotec. It is designed for the detection and analysis of cellular antigens through flow cytometry applications.

Automatically generated - may contain errors

2 protocols using sc 13118 fitc

1

Quantitative nEV Surface Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
Approximately 1011 nEVs from SK-N-BE(2), MDA-MB-231 and SW620 cells, respectively, were re-suspended in 100 μl of SFM and labelled with 5 nmol of LP following the above protocol. nEVs were directly anchored onto NA coated glass substrate after incubation at RT for 30 min. All samples were fixed with 1× stabilizing fixative (BD, Biosciences) for 10 min followed by PBS rinsing thrice. Surface was blocked with 1% BSA in PBS for 30 min at RT and incubated overnight at 4 °C with the following fluorescence conjugated antibodies against CD9 (Santa Cruz Biotechnology, sc-13118 FITC) and CD326 (EpCAM, Miltenyl Biotec, 130-098-115). Afterwards, samples were thoroughly washed with PBS and observed under fluorescence microscopy (Olympus). Fluorescence intensity was quantified with ImageJ.
+ Open protocol
+ Expand
2

Quantitative nEV Surface Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
Approximately 1011 nEVs from SK-N-BE(2), MDA-MB-231 and SW620 cells, respectively, were re-suspended in 100 μl of SFM and labelled with 5 nmol of LP following the above protocol. nEVs were directly anchored onto NA coated glass substrate after incubation at RT for 30 min. All samples were fixed with 1× stabilizing fixative (BD, Biosciences) for 10 min followed by PBS rinsing thrice. Surface was blocked with 1% BSA in PBS for 30 min at RT and incubated overnight at 4 °C with the following fluorescence conjugated antibodies against CD9 (Santa Cruz Biotechnology, sc-13118 FITC) and CD326 (EpCAM, Miltenyl Biotec, 130-098-115). Afterwards, samples were thoroughly washed with PBS and observed under fluorescence microscopy (Olympus). Fluorescence intensity was quantified with ImageJ.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!