310 ms lc ms ms triple quadrupole mass spectrometer

Manufactured by Agilent Technologies

The 310—MS LC/MS/MS triple quadrupole mass spectrometer is a highly sensitive and precise analytical instrument designed for the quantitative analysis of small molecules. It combines liquid chromatography (LC) with tandem mass spectrometry (MS/MS) technology to provide accurate and reliable results. The core function of this system is to separate, detect, and quantify target analytes in complex samples with high specificity and selectivity.

Automatically generated - may contain errors

2 protocols using 310 ms lc ms ms triple quadrupole mass spectrometer

1

Synthesis and Characterization of Novel Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents, solvents, and chemical materials were purchased from Merck and Chimopar and used as received. Compounds 1 and 5 were commercially available; compounds 24, and 8 are known in the literature and we therefore synthesized them following similar methods [14 (link),15 (link),16 (link),17 (link)]; compounds 7 and 9 are new derivatives obtained, and their physico-chemical characteristics are presented in detail. The purity of all compounds was checked with TLC (single spot).
UV-Vis measurements were performed in methanol, using a UVD-3500 UV-Vis double-bean spectrophotometer.
IR spectra were measured using a Bruker Tensor 27 FT-IR spectrometer.
NMR spectra were measured in chloroform-d1 or DMSO-d6 using a Bruker Advance spectrometer operating at 500 MHz for 1H and 125 MHz for 13C. We report the chemical shifts δ as ppm values and the residual solvent peaks were used as an internal reference. For the MS spectra, we used a Varian 310—MS LC/MS/MS triple quadrupole mass spectrometer fitted with an electrospray ionization interface (ESI).
+ Open protocol
+ Expand
2

Multimodal Characterization of Compound 3

Check if the same lab product or an alternative is used in the 5 most similar protocols
IR spectra were measured using a Bruker Tensor 27 FT-IR spectrometer (ATR). UV-Vis measurements were performed in DCM using a Cary 4000 UV-Vis Agilent Technologies spectrophotometer. Fluorescence measurements were performed in DCM using a lifetime and steady-state spectrometer-FLSP 920, Edinburgh Instruments. Regarding the NMR spectra, these were measured in chloroform-d1 or DMSO-d6 using a Bruker Advance spectrometer operating at 500 MHz for 1H and 125 MHz for 13C. As usual, the chemical shifts are reported as δ ppm values, and the residual solvent peaks were used as the internal reference. A Varian 310—MS LC/MS/MS triple quadrupole mass spectrometer fitted with an electrospray–ionisation interface (ESI) was used for the MS spectra. The ESR spectrum was recorded on a Jes-FA 100 Jeol Instrument. For the X-ray diffraction measurements for compound 3 employed a Rigaku XtaLAB Synergy-S diffractometer operating with an Mo-K (λ = 0.71073 Å) micro-focus sealed X-ray tube. The structure was solved using direct methods and refined by full-matrix least-squares techniques based on F2. The non-H atoms were refined with anisotropic displacement parameters. The SHELX-2018 crystallographic software package was used for calculations. The crystallographic data summary and the structure refinement for compound 3 are given in Table 3. CCDC reference number: 2280342.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.