The largest database of trusted experimental protocols

2 protocols using ly49a d pe

1

Multiparameter Flow Cytometry Staining

Check if the same lab product or an alternative is used in the 5 most similar protocols
Samples were stained with a 2.4G2 blocking antibody and monoclonal antibodies in 1% PBS-serum for 20 minutes on ice in the dark. For samples stained with CD1 tetramer, cells were incubated for 15 minutes at room temperature in the dark, followed by 15 minutes on ice in the dark. Samples requiring intracellular staining were then fixed and permeabilized using CytoFix/CytoPerm (BD Biosciences) and stained with intracellular antibodies for 15 minutes on ice in the dark. Events were collected on either a FACSAria (BD Biosciences) or a MACSQuant (Miltenyi Biotec). Data were analyzed using FlowJo (Tree Star Inc.). IL-17A-AlexaFluor488, CD45.2-FITC, HSA-FITC, TCRβ-FITC, TCRVβ2-FITC, CD45.1-PE, PLZF-PE, TCRβ-PE, Foxp3-PE-Cy5.5, NK1.1-PerCPCy5.5, TCRβ-PErCPCy5.5, RORγt-PerCPeFluor710, TCRβ8.1/2-PerCPeFluor710, Ly49G2-PerCPeFluor710, IFN-γ-PE-Cy7, NK1.1-PE-Cy7, T-Bet-PE-Cy7, CD45.1-APC, CD25-APC, IL-4-APC, CD4-APCeFluor780, CD44-APCeFluor780, CD45.2-APCeFluor780, CD90.1-APCeFluor780, CD8α-eFluor450, CD3-eFluor450, Ki67-eFluor450, and TNF-α-eFluor540 were purchased from eBioscience (San Diego, CA). Ly49C/I-FITC, Ly49A/D-PE, and CD4-PerCP were purchased from BD Pharmingen. TCRVβ7-PE was purchased from Biolegend. CD1d tetramer loaded with α-GalCer, CD1d tetramer loaded with PBS-57 as well as unloaded controls were provided by the NIH Tetramer Facility.
+ Open protocol
+ Expand
2

Multiparameter Flow Cytometry Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cells were stained with fluorochrome-conjugated monoclonal antibodies and 2.4G2 blocking antibody and incubated in the dark for 30 min on ice. For CD1d tetramer staining, cells were incubated in the dark for 15 min at room temperature followed by 15 min on ice. Flow cytometric analysis was performed on a FACSAria (BD Biosciences) or a MACSQuant (Miltenyi Biotec). Data were analyzed using FlowJo (Tree Star).
TCRβ-FITC, HSA-FITC, CD4-FITC, TCRβ-PE, Ly49C/I/F/H-PE, TCRβ-PErCPCy5.5, Ly49G2-PerCPeFluor710, CD62L-PE-Cy6, NK1.1-PE-Cy7, KLRG1-APC, CD25-APC, CD19-PE, CD44-APCeFluor780, CD8α-eFluor450, and CD3-eFluor450 were purchased from ebioscience. Ly49G2-FITC, Ly49C/I-FITC, Ly49A/D-PE, and CD4-PerCP were purchased from BD Pharmingen. BV421-CD127, BV510-TCRβ, BV570-CD45, BV605-CD3, BV605-CCR6, and BV785-NK1.1 were purchased from Biolegend. PE- and APC-conjugated α-GalCer loaded CD1d tetramer was prepared in our laboratory. CD1d, M45 and M57 tetramers were kindly provided by the National Institute of Allergy and Infectious Disease MHC Tetramer Core Facility at Emory University (Atlanta, GA, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!