The largest database of trusted experimental protocols

Atr pro one accessory

Manufactured by Jasco
Sourced in Japan

The ATR Pro One accessory is a compact and versatile device designed to be used in conjunction with compatible Fourier Transform Infrared (FTIR) spectrometers. Its core function is to facilitate Attenuated Total Reflectance (ATR) measurements, which allows for the non-destructive analysis of a wide range of solid, liquid, and semi-solid samples.

Automatically generated - may contain errors

4 protocols using atr pro one accessory

1

FTIR Characterization of Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
Conventional infrared absorption spectra are measured using a Jasco 4700 FTIR spectrometer in attenuated total reflection (ATR) geometries. For the ATR experiments, the Jasco ATR Pro One accessory equipped with a diamond crystal is used. The spectra are averaged over 40 scans and are acquired with a resolution of 2 cm−1.
+ Open protocol
+ Expand
2

FTIR Spectroscopy of Molecular Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
Conventional infrared absorption spectra were measured using a Jasco 4700 FTIR spectrometer both in transmission and attenuated total reflection (ATR) geometries. For the ATR experiments, the Jasco ATR-Pro One accessory equipped with a diamond crystal was used. The spectra were averaged over 20 scans and were acquired with a 2 cm−1 resolution, close to the resolution of the corresponding picosecond NTA experiments.
+ Open protocol
+ Expand
3

Attenuated Total Reflectance FTIR Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The attenuated total reflectance-Fourier transform infrared spectra of films were obtained with a Jasco FT/IR-4600 equipped with the ATR Pro One accessory with an internal reflectance element of ZnSe (wave number range of 15,000–550 cm−1) (Jasco Corporation, Tokyo, Japan). Determinations were conducted in triplicate. The spectra were measured between 400 and 4000 cm−1 by co-adding 16 scans at 1 cm−1 resolution. Data treatments were performed with PeakFit software version 4.12 (SYSTAT Software, Richmond, CA, USA), according to Díaz et al. [3 (link)].
+ Open protocol
+ Expand
4

FT-IR Spectroscopy Analysis Procedure

Check if the same lab product or an alternative is used in the 5 most similar protocols
The analysis was carried out in FT-IR -6800 (Jasco, Japan) equipped with ATR PRO ONE accessory and TGS detector. Registration was carried out in the region of 400 -4000 cm -1 (resolution 4 cm -1 with 40 number of scanes). The report was then processed using origin ® 8.0 software and interpreted.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!