The largest database of trusted experimental protocols

Avance av 400 mhz

Manufactured by Bruker
Sourced in Switzerland

The Avance AV 400 MHz is a nuclear magnetic resonance (NMR) spectrometer manufactured by Bruker. It operates at a frequency of 400 MHz and is designed for high-resolution NMR analysis of chemical and biological samples.

Automatically generated - may contain errors

2 protocols using avance av 400 mhz

1

Synthesis of Fluorinated Dimethacrylate (FDMA)

Check if the same lab product or an alternative is used in the 5 most similar protocols
FDMA was synthesized according to the reaction route shown in Scheme 1. Firstly, a urethane precursor was synthesized through the reaction between (22.23 g, 0.10 mol) IPDI (1) and (23.11 g, 0.05 mol) PFDOL (2) at 45 °C. In this reaction, THF and a few droplets of DBTDL were used as the solvent and catalyst, respectively. When the -NCO groups content reached half of the initial content (determined by dibutyl amine titration) to form (3), 13.01 g (0.10 mol) of HEMA (4) were added into the reactor and the reaction was continued under 45 °C. The reaction was stopped until the infrared absorbance peak of the -NCO group (2270 cm−1) disappeared in the FT-IR (Fourier Transform Infrared; Vector33, Bruker Co., Bremen, Germany) spectra of the samples taken from the reaction medium every 1 h. After removing the THF by distillation under vacuum, the product FDMA (5) was obtained as a colorless viscose liquid. The structure of FDMA was investigated by FT-IR and 1H-NMR (Proton Nuclear Magnetic Resonance Instrument; Avance AV 400 MHz, Bruker Co., Fällanden, Switzerland) spectra.
+ Open protocol
+ Expand
2

Synthesis of Novel Oxadiazole and Acetamide Derivatives

Check if the same lab product or an alternative is used in the 5 most similar protocols
Chemicals were purchased from Sigma Aldrich (St. Louis, MO, USA) and Alfa Aesar (Ward Hill, MA, USA). Melting points were taken on Griffin and George melting point apparatus using the open capillary tube method and were reported as uncorrected. Infrared spectra were recorded in KBr on a Jasco-320-A spectrophotometer. 1H-NMR signals were recorded on AVANCE AV-300 MHz, AVANCE AV-400 MHz, or AVANCE AV-500 MHz while 13C-NMR spectra were taken on a Bruker AVANCE AV-75 MHz, AVANCE AV-100 MHz and AVANCE AV-125 MHz spectrometer. EIMS signals were recorded on JEOL MS 600H-1 spectrometer. 5-[2-(4-Chlorophenoxy)propan-2-yl]-1,3,4-oxadiazol-2-thiol 1 [29 ] and aromatic N-substituted-2-bromoacetamides (2a2i) were synthesized by previously reported methods with slight modifications [12 ].
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!