Symbia t6 spect ct system

Manufactured by Siemens
Sourced in Germany

The Symbia T6 SPECT/CT system is a diagnostic imaging device that combines single-photon emission computed tomography (SPECT) and computed tomography (CT) technologies. It is designed to acquire and integrate functional and anatomical information for clinical evaluation.

Automatically generated - may contain errors

Lab products found in correlation

4 protocols using symbia t6 spect ct system

1

MP-SPECT Cardiac Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Patients were assessed by MP-SPECT using a Symbia T6 SPECT-CT system (Siemens, Erlangen, Germany; Siemens Japan, Tokyo, Japan). The equipment consisted of a dual-head gamma camera in 180° geometry equipped with a low-energy, high-resolution (LEHR) collimator. The SPECT data were acquired in a 64 × 64 matrix using the following parameters: zoom, × 1.45; pixel size, 6.6 mm, duration, and 35 s per projection for a total acquisition period of 20 min. We obtained a total of 60 frames, at 6° per step over 360°. The cardiac cycle was divided into 16 frames for electrocardiography (ECG) gating. R-R intervals that averaged ± 25% on the ECG monitor were accepted for gating. The energy was centered at 140 keV, with a 15% window for SPECT/CT imaging. Scatter and attenuation were not corrected. The detectors were placed close to the patient in circular mode at a radius of 24–25 cm.
+ Open protocol
+ Expand
2

SPECT/CT Imaging of Radiotherapeutic Agents

Check if the same lab product or an alternative is used in the 5 most similar protocols
SPECT/CT imaging of the abdomen was performed 24 hours after the injection of the radiotherapeutic agent. The images were acquired with a Symbia T6 SPECT/CT system (Siemens Healthineers AG, Erlangen, Germany; matrix: 128 × 128; 64 views of 20 seconds). SPECT images were reconstructed with an OSEM-based Flash 3D algorithm (8 iterations, 4 subsets, and 8 mm Gaussian filtering). For 90Y/111In-DOTATOC, a scatter and attenuation correction was performed. Additionally, at 3 and 48 hours postinjection (p.i.), scintigraphy was performed to monitor radiation exposure of the kidneys and whole body assessment, respectively.
+ Open protocol
+ Expand
3

Dual-Head SPECT/CT Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
A dual-head Symbia T6 SPECT/CT system (Siemens Healthineers, Erlangen, Germany) with a NaI crystal thickness of 9.5 mm and equipped with a medium energy low penetration collimator was used.
+ Open protocol
+ Expand
4

SPECT/CT Imaging of Radiolabeled GSA

Check if the same lab product or an alternative is used in the 5 most similar protocols
Images were acquired using a Siemens Symbia T6 SPECT/CT system. Before imaging, 3 mg of GSA (185MBq) (Beijing Shihong Drug Research Center, Beijing, P.R.C.) was labeled with 99mTc and allowed to stand for at least 10 minutes before injection. Patients were imaged in the supine position on the examination table with their hands placed on the sides of their head. The SPECT detectors were positioned toward the patient's liver and SPECT acquisition was started as soon as the intravenous bolus injection of the radiopharmaceutical was complete. The SPECT dual heads continuously rotated through 180 degrees with a radius 26 cm at a speed of 1 min/rotation. Twenty-six frames of tomographic images were acquired. The acquisition time per frame was 1 minute for the first 25 frames and 5 minutes for the last frame.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!