Chemstation lc 3d software

Manufactured by Agilent Technologies

Chemstation LC 3D software is a data analysis and instrument control software for liquid chromatography (LC) systems. It provides tools for data acquisition, processing, and reporting. The software supports 3D data visualization and comprehensive data analysis.

Automatically generated - may contain errors

2 protocols using chemstation lc 3d software

1

HPLC Analysis of Drug Loading and Release

Check if the same lab product or an alternative is used in the 5 most similar protocols
Drug loading and drug release were measured using an Agilent 1200 Series HPLC system, which consisted of a quaternary pump, online degasser, manual injector with a 20-µl sample loop and Agilent Chemstation LC 3D software. Chromatography was conducted in reverse mode using acetonitrile and phosphate buffer (0.05 M, pH 5.65). A gradient at 40% for 1 min, raised to 60% in 14 min, was reduced to 40% in 1 min and held at 40% for 4 min. Total analysis time was 20 min. Mobile phase flow rate was 1.5 ml/min, with a column temperature at 30 °C and a sample injection volume of 5 µl. Detection was performed with a diode array detector at 240 nm for RTV and EFV. The drug concentration was obtained from calibration curves for RTV and EFV.
+ Open protocol
+ Expand
2

Size-Exclusion Chromatography for Protein Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Size-exclusion chromatography (SEC) was performed under isocratic elution conditions with a HiLoad 16/600 Superdex 200 preparative grade column (10,000–600,000 relative molecular mass (Mr) range, GE Healthcare, Chicago, IL, USA) and a HiLoad 16/600 Superdex 75 preparative grade column (3,000–70,000 Mr range, GE Healthcare) for the analysis of SDP and EHPP, respectively, using an HP 1100 series liquid chromatograph with an ultraviolet absorption diode array detector (Agilent Technologies, Waldbronn, Germany). Instrument control, data acquisition and data processing were performed using the Chemstation LC3D software (Agilent Technologies). The mobile phase consisted of phosphate buffered saline (PBS, pH = 7.50) and absorbance was monitored at 214 nm. After column equilibration with mobile phase (two column volumes), a calibration curve was constructed by injecting 1 mL of a 500 mg/L mixture of protein standards of known Mr according to the manufacturer instructions. SDP and EHPP were analyzed by injecting volumes of 1 mL, and fractions (for EHPP only) were collected using an Agilent 1200 series analytical fraction collector (Agilent Technologies).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!