The largest database of trusted experimental protocols

2 protocols using recombinant mouse cst6

1

Fluorometric Assay of Cysteine Protease Inhibition

Check if the same lab product or an alternative is used in the 5 most similar protocols
Protease inhibitor activity of recombinant mouse Cst6 (R&D Systems) against recombinant mouse CtsB (R&D Systems) was determined by measuring the hydrolysis of the fluorescent Z-Leu-Arg-AMC substrate (R&D Systems) (4 (link)). Assays were performed in a 25 mM 2-(N-morpholino)ethanesulfonic acid buffer (pH 5.0). The CtsB inhibitor CA-074 (Brunschwig Chemie) was used as the control.
+ Open protocol
+ Expand
2

Quantification of Mouse and Human Cystatin E/M

Check if the same lab product or an alternative is used in the 5 most similar protocols
Recombinant mouse Cst6 and human CST6 (both from R&D Systems, Minneapolis, MN, USA) were used as a standard and as a negative control, respectively, in concentrations varying from 5 to 0.156 ng/ml. The wells of a 96-well plate were coated overnight at 4°C with polyclonal rabbit anti-human CST6 antibody (2 (link)), followed by incubation with 1% bovine serum albumin (ICN Biomedicals, Aurora, OH, USA) and 1% normal goat serum (Vector Laboratories, Burlingame, CA, USA) in PBS for 30 min. Subsequently, standards, controls, and samples (undiluted up to 32× diluted) were incubated for 1 h, followed by incubation with monoclonal rat anti-mouse Cst6 (R&D Systems) in PBS/1% normal rabbit serum/0.1% bovine serum albumin/0.05% Tween-20 for 30 min. Next, wells were incubated with goat anti-rat biotinylated antibody (Vector Laboratories) for 30 min, followed by a final incubation with avidin-biotinylated horseradish peroxidase complex (Vector Laboratories) for 30 min. The above incubation steps were performed at 37°C and separated by repeated washing steps with PBS/0.05% Tween-20. Chromogenic substrate 1-step Ultra TMB (Thermo Fisher Scientific) was used as substrate for detection and the reaction was stopped by adding 4 M H2SO4. Each well was measured for mouse Cst6 at an absorbance of 450 nm with an ELISA microplate reader (Bio-Rad, Hercules, CA, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!