The largest database of trusted experimental protocols

Nicolet is50 ftir nir spectrometer

Manufactured by Thermo Fisher Scientific
Sourced in United States

The Nicolet iS50 FTIR + NIR Spectrometer is a versatile laboratory instrument that combines Fourier Transform Infrared (FTIR) and Near-Infrared (NIR) spectroscopy capabilities. It is designed to provide accurate and reliable analysis of a wide range of samples by detecting and identifying chemical compounds and their molecular structures.

Automatically generated - may contain errors

2 protocols using nicolet is50 ftir nir spectrometer

1

FTIR Analysis of Rosmarinic Acid in NADES

Check if the same lab product or an alternative is used in the 5 most similar protocols
Sample in FTIR assay was 10 mg of rosmarinic acid standard, 10 mL of NADES betain-urea liquid and 10 mL of 1% mixture of rosmarinic acid standard in NADES betain-urea. The FTIR test was carried out using the Thermo Scientific - Nicolet iS50 FTIR + NIR Spectrometer provided by the ILRC laboratory of the University of Indonesia. The FTIR spectra was observed structural changes of rosmarinic acid due to solvation in NADES.
+ Open protocol
+ Expand
2

Menadione Spectroscopic Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Menadione of high purity (>98%) purchased from Sigma Aldrich (St. Louis, MO, USA) was used as received. MIR spectra were measured by attenuated total reflection (ATR) and diffuse reflectance (DRIFT) techniques on a Nicolet iS50 FT-IR/NIR spectrometer (Thermo Fisher Scientific, Waltham, MA, USA) using KBr beamsplitter and DTGS/KBr detector. IR spectra were measured in the 4000–400 cm−1 range with a resolution of 2 cm−1 and 512 scans were accumulated. DRIFT spectra were measured with the Collector accessory. The sample was mixed with dry KBr to obtain approx. 2% (w/w) solid solution. The sample was prepared directly before the spectral measurements. ATR-IR spectra were acquired by ATR Smart Golden Gate accessory (single reflection, 45° incident angle) with diamond internal reflection element (IRE). Next, the spectra were subjected to ATR correction using the refractive index of the IRE and the sample. NIR spectra were measured on Nicolet iS50 spectrometer (Thermo Fisher Scientific, Waltham, MA, USA), with CaF2 beamsplitter and DTGS/KBr detector. The spectra were collected in the 10,000–4000 cm−1 range with resolution of 4 cm−1 and 256 scans were accumulated.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists