The largest database of trusted experimental protocols

82 protocols using chromasolv

1

Simultaneous Quantification of Vitamin D Metabolites

Check if the same lab product or an alternative is used in the 5 most similar protocols
Standard references for vitamin D3, d3-vitamin D3 (6,19,19-d3) as internal standard, 25(OH)D3, d6-25(OH)D3 (26,26,26,27,27,27-d6) as internal standard, and 1,25(OH)2D3 were purchased from Cerilliant, TX, USA. 4-Phenyl-1,2,4-triazoline-3,5-dione (LiChropur for LC-MS) dissolved in acetonitrile was used for derivatization. All solvents were of high-purity LCMS grade: methanol (ChromaSolv®, Sigma-Aldrich, St. Louis, MO, USA), n-hexane (Hipersolv Chromanorm®, Sigma-Aldrich, St. Louis, MO, USA), methyl-tert-butyl-ether (ChromaSolv®, Sigma-Aldrich, St. Louis, MO, USA), acetonitrile (ChromaSolv®, Sigma-Aldrich, St. Louis, MO, USA), and formic acid (Scharlau, Sentmenat, Spain) were used. A Millipore Direct-Q water purification system (Millipore, Bedford, MA, USA) provided the water.
+ Open protocol
+ Expand
2

HPLC Solvent Preparation for Mass Spectrometry

Check if the same lab product or an alternative is used in the 5 most similar protocols
Extraction solvents: water was supplied by a Millipore (Solna, Sweden) system. Methanol (Chromasolv for gradient elution) and acetone (Chromasolv for HPLC) were purchased from Sigma-Aldrich (Stockholm, Sweden).
Chromatography solvents: Water was supplied by a Millipore system. Acetonitrile (ACN) (LC-MS Chromasolv grade), ammonium formate (for LC-MS), and formic acid (for LC-MS) were obtained from Sigma-Aldrich (Stockholm, Sweden).
+ Open protocol
+ Expand
3

Synthesis and Purification of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All precursors for the synthesis and solvents were obtained from Sigma-Aldrich (Merck KGaA, Saint Louis, MO, USA) and were used as received without further purification. Spectral grade solvent (CDCl3) was stored over 3 Å molecular sieves for several days. Thin layer chromatography (TLC) was carried out on precoated plates (TLC silica gel 60 F254, Aluminum Plates Merck, Merck KGaA, Saint Louis, MO, USA) and spots were detected by illumination with a UV lamp. All the solvents used in flash chromatography were of HPLC grade (CHROMASOLV from Sigma-Aldrich, Merck KGaA, Saint Louis, MO, USA) and were used as received. The elemental analysis of compounds was carried out on Vario ELIII (Elementar, Langenselbold, Germany).
+ Open protocol
+ Expand
4

Determination of Peroxide Levels in Household Items

Check if the same lab product or an alternative is used in the 5 most similar protocols
Hydrogen peroxide pure (Warchem, PL), with a nominal concentration 60% w/w and an actual concentration 56 ± 1% w/w, was used without purification; the concentration was determined by the standard iodometric procedure.
Phosphorus pentoxide (anhydrous, ReagentPlus®), methanol (Chromasolv®), n-dodecane (ReagentPlus®), and potassium bromide (Uvasol®) were obtained from Merck Life Science Sp.z.o.o. (PL).
Peroxides were detected in an aqueous solution using the peroxide strip test XploSens PS™ (Xplosafe LLC, USA).
Ground turmeric and sweet paprika (Kamis brand, McCormick Polska S.A., PL), ground coffee (Prima brand, Jacobs Douwe Egberts PL sp z.o.o., PL), and black tea from teabags (Minutka brand, Mokate S.A., PL) were used as obtained.
+ Open protocol
+ Expand
5

Quantification of C60 Fullerene Isotopes

Check if the same lab product or an alternative is used in the 5 most similar protocols
C 60 fullerene (sublimed, 99.9% purity; reference 572500) was purchased from Sigma-Aldrich (Steinheim, Germany). 13 C-enriched C 60 fullerene (> 99% purity; abbrev. 13 C 60 ; reference MRL613) was purchased from MER Corporation (Tucson, AZ, USA).
Methanol and ultrapure water (Optima® LC/MS grade) were purchased from Fischer Chemical (Loughborough, UK) and toluene (Chromasolv®) was purchased from Merck (Darmstadt, Germany).
Stock solutions of C 60 fullerene and 13 C 60 for LC-HRMS analyses were prepared in toluene at 1000 ng/μL, while the final calibration curve was prepared in 90:10 toluene:methanol.
+ Open protocol
+ Expand
6

Spectrophotometric Determination Protocols

Check if the same lab product or an alternative is used in the 5 most similar protocols
The reagents used for spectrophotometric determinations (sodium acetate, aluminum chloride, Folin–Ciocalteu phenol reagent, reagent-grade sodium carbonate, sodium acetate buffer, potassium chloride buffer) and solvents were bought from Merck (Darmstadt, Germany)
All standards and solvents were of HPLC (Chromasolv) quality and were purchased either from Sigma-Aldrich or from Merck (Darmstadt, Germany). The pure compounds used as standards were obtained from Sigma-Aldrich (Darmstadt, Germany) and the purity grade was at least 95%.
+ Open protocol
+ Expand
7

Analytical Standards for Mass Spectrometry

Check if the same lab product or an alternative is used in the 5 most similar protocols
Methanol (99.9% Chromasolv) was obtained from Fluka (Sigma-Aldrich Denmark, Copenhagen, Denmark), acetonitrile (LC-MS Chromasolv) was from Riedel-de-Haën (Sigma-Aldrich Denmark, Copenhagen, Denmark) and water was Milli-Q-filtered water (Elga, Krüger Aquacare, Glostrup, Denmark). Ammonium acetate (99.999 trace metal basis), 2,5-dihydroxybenzoic acid (>99 %, matrix substance for MALDI-MS), dextran (MW ~ 6000), and polyethylene glycol 1500 were obtained from Sigma-Aldrich (Saint Louis, MO, USA).The following authentic standards were used: tetramethoxysilane, trimethoxymethylsilane, trimethoxyoctylsilane, hexamethylcyclotrisiloxane, octamethylcyclotetra- siloxane, 2-pyrrolidone, tetradecanoic acid methyl ester, pentadecanoic acid methyl ester, hexadecanoic acid methyl ester, octadecanoic acid methyl ester, tetradecanoic acid, hexadecanoic acid, and octadecanoic acid (all >99% purity; Sigma-Aldrich, Saint Louis, MO, USA). Alkyltrimethylammonium chloride with C16 (>98%) and C18 (>95%) alkyl chains, dimethyldialkylammonium chlorides or bromides with C14 (>97%), C16 (97%) and C18 (>97%) alkyl chains, and benzalkonium chloride with a C12 alkyl chain were also obtained from Sigma Aldrich.
+ Open protocol
+ Expand
8

Quantification of Endocannabinoids and Metabolites

Check if the same lab product or an alternative is used in the 5 most similar protocols
OEA, PEA, the deuterated standards D9-progesterone and D7-cortisone, and 13C-labeled standards 13C3-androstenedione, 13C3-testosterone, and 13C3-progesterone were purchased from Sigma-Aldrich (Buchs, Switzerland). 13C3-cortisol and 13C3-cortisone were purchased from Isoscience (Ambler, USA). AEA, 2-AG, and the deuterated eCBs (D4-AEA, D5-2-AG, D4-OEA, D4-PEA, and D11-AEA) were purchased from Cayman Chemicals (Ann Arbor, USA). Water and methanol (MeOH) were of LC–MS grade (Chromasolv®) and purchased from Sigma-Aldrich (Buchs SG, Switzerland). Acetone, ethyl acetate, and ammonium fluoride were purchased from Merck (Darmstadt, Germany). Reconstitution solution consisted of 0.2 mM NH4F in water/methanol 97/3 v/v, respectively. Isolute® SLE + columns were purchased from Biotage® (Uppsala, Sweden). All chemicals were of highest analytical grade.
+ Open protocol
+ Expand
9

Antioxidant Compound Extraction Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Choline chloride (≥99%), lactic acid (∼90%), 1.2-propanediol (≥99%), ethanol (reagent), methanol (CHROMASOLV®  ≥ 99.9%), water (CHROMASOLV® Plus grade HPLC), 2,2,1-diphenyl-1-picrylhydrazyl (DPPH), 6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid (Trolox) gallic, ferulic, p-coumaric, sinapic and vanillic acids were obtained from Sigma-Aldrich (St. Louis, MO, USA).
+ Open protocol
+ Expand
10

Acetobromination and GPC Analysis of Lignin

Check if the same lab product or an alternative is used in the 5 most similar protocols
For GPC,
approx. 5 mg of lignin or lignin
derivative were acetobrominated40 (link) and redissolved
in tetrahydrofuran (THF) (3 mg/mL). Analysis was performed as detailed
before,41 (link) omitting the determination of
correction factors. Analyses were performed using the Shimadzu hardware
components described in Method A, employing three analytical GPC columns
(each 7.5 × 30 mm) in series for analyses: Agilent PLgel 5 μm
10000 Å, followed by Agilent PLgel 5 μm 1000 Å, followed
by an Agilent PLgel 5 μm 500 Å. High-performance liquid
chromatography (HPLC)-grade THF (Chromasolv, Sigma-Aldrich) was used
as eluent (0.75 mL min–1 for 70 min at 40 °C
column temperature). Standard calibration was performed with polystyrene
standards (Sigma-Aldrich, MW range 0.162–5000 kDa). Analyses
were run in duplicate.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists