The largest database of trusted experimental protocols

Murine anti cd40 fitc

Manufactured by BD

Murine anti-CD40-FITC is a fluorescently labeled antibody that binds to the CD40 receptor on the surface of cells. It can be used in flow cytometry applications to detect and analyze CD40-expressing cells.

Automatically generated - may contain errors

2 protocols using murine anti cd40 fitc

1

Multiparameter Flow Cytometry Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Tissues were processed using methods described previously26 . 200,000 cells were stained for 30 minutes (1:100) to antibodies: CCR2-PE (RnD Systems cat no.FAB5538P), CD24-Brilliant Violet (BD Pharmingen cat no.562563), F4/80-PE (Serotec cat no.MCA497PE), CD69-FITC (Biolegend cat no.104505), CD4-PE-Cy5 (BD Pharmingen cat no.553654), CD8-APC (Biolegend cat no.100711), CD11b-APC-Cy7 (BD Pharmingen cat no.557657), human anti-CD40-FITC (R&D Systems, cat no.MAB6321) or murine anti-CD40-FITC (BD Biosciences cat no.12040181). Cells were analyzed using a BD LSR II flow cytometer. Compensation controls were performed to minimize spectral overlap artifacts. Isotype control antibodies were utilized for background correction.
+ Open protocol
+ Expand
2

Multiparameter Flow Cytometry Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Tissues were processed using methods described previously26 . 200,000 cells were stained for 30 minutes (1:100) to antibodies: CCR2-PE (RnD Systems cat no.FAB5538P), CD24-Brilliant Violet (BD Pharmingen cat no.562563), F4/80-PE (Serotec cat no.MCA497PE), CD69-FITC (Biolegend cat no.104505), CD4-PE-Cy5 (BD Pharmingen cat no.553654), CD8-APC (Biolegend cat no.100711), CD11b-APC-Cy7 (BD Pharmingen cat no.557657), human anti-CD40-FITC (R&D Systems, cat no.MAB6321) or murine anti-CD40-FITC (BD Biosciences cat no.12040181). Cells were analyzed using a BD LSR II flow cytometer. Compensation controls were performed to minimize spectral overlap artifacts. Isotype control antibodies were utilized for background correction.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!