The largest database of trusted experimental protocols

Trace 1310 gc tcd

Manufactured by Thermo Fisher Scientific
Sourced in Denmark

The Trace 1310 GC-TCD is a gas chromatography system equipped with a thermal conductivity detector (TCD). It is designed for the analysis and quantification of various chemical compounds in complex samples. The system offers reliable performance and precise detection capabilities.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using trace 1310 gc tcd

1

Wastewater Characterization and Biogas Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
TS, VS, TAN and TKN were measured using APHA's Standard Methods (APHA, 2013) and pH values with PHM99 LAB pH meter. Sulphate concentration in wastewaters was measured using Spectroquant® Sulphate Cell Test (Merck, Denmark). The wastewater samples were previously filtered at 0.45 µm with Millex-HV13 Filter Unit (Merck, Denmark). The total VFA concentrations of the inoculum and the wastewaters were the sum their individual VFA concentrations (i.e. acetate, propionate, iso-butyrate, butyrate, iso-valerate, valerate and hexanoate), which were determined with a gas-chromatograph (HP 5890 series II, Hewlett Packard, US) equipped with flame ionization detector and a FFAP fused silica capillary column, (30 m x 0.53 mm i.d., film thickness 1.5 µm), and nitrogen as a carrier gas. The biogas composition was measured with a gas-chromatograph (Trace 1310 GC-TCD, Thermo Fisher, Denmark) equipped with Trace PLOT TG-BOND Q 26004-6030 column (30 m x 0.32 mm I.D., film thickness 10.0 µm; Thermo Fisher, Denmark) and helium was used as carrier gas for both methane, carbon dioxide, and hydrogen sulphide.
+ Open protocol
+ Expand
2

Methane Quantification in Batch Reactors

Check if the same lab product or an alternative is used in the 5 most similar protocols
Methane accumulation in the headspace of the batch reactors was determined by a gas chromatographer (Trace 1310 GC-TCD, Thermo Fisher, Denmark) equipped with a
TracePLOT TG-BOND Q 26004-6030 column (30 m x 0.32 mm I.D., film thickness 10 μm) (Thermo Fisher), and helium was used as carrier gas (Tian et al., 2017) . The pH of each reactor was measured with PHM99 LAB pH meter (Radiometer TM).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!