The largest database of trusted experimental protocols

120 protocols using immunocap system

1

Anisakis-specific IgE Determination

Check if the same lab product or an alternative is used in the 5 most similar protocols
All allergic patients and 21 out of 47 of the enrolled sABD underwent SPT to A. simplex using commercial extracts (Laboratorios LETI, Spain; 165 mcg/mL). SPTs were performed on the volar side of the forearm by using disposable 1-mm-tip lancets and were also conducted with histamine (Roxall; 10 mg/ml) as positive and saline solution (0.9% NaCl) as negative controls. Readings were taken at 20 min after application. A mean wheal diameter of ≥ 3 mm was considered positive. sIgE to whole A. simplex extract (Anisakis-sIgE) was determined by ImmunoCAP system (Thermo Fisher Scientific Inc., Uppsala, Sweden) according to the manufacturer’s instructions. A positive result was considered Anisakis-sIgE > 0.35 kUA/l. The same method was used to determinate total IgE, and sIgE to fish.
+ Open protocol
+ Expand
2

Determining IgE Levels with Immunoassay

Check if the same lab product or an alternative is used in the 5 most similar protocols
IgE level determinations were performed using the Immuno-CAP system at Thermo Fisher (Allerød, Denmark) on native and IgE-depleted sera (see above). Determination of specific IgE before and after depletion was performed to confirm that componentspecific IgE was effectively removed by ImmunoCAP treatment without affecting the other component-specific IgEs. To exclude that the ImmunoCAP treatment itself impacted the level of specific IgE, serum depletion with an ECP ImmunoCAP was included as control. Furthermore, an IgE depletion by peanut ImmunoCAP was included to demonstrate that all IgE specificities against peanut were removed (for further details refer to online supplementary material).
+ Open protocol
+ Expand
3

Serum IgG4 and IgE Determination

Check if the same lab product or an alternative is used in the 5 most similar protocols
The determination of specific IgG 4 and IgE to DP and DF was performed using the ImmunoCAP system (Thermo Fisher, Waltham, Mass., USA). Serum samples for IgG 4 determination were diluted 1:50 before analysis.
+ Open protocol
+ Expand
4

Serum IgE Measurement by ImmunoCAP

Check if the same lab product or an alternative is used in the 5 most similar protocols
Total and allergen-specific (SX-1) IgE concentrations in serum were determined using the ImmunoCAP system (Thermo Fisher Scientific, Uppsala, Sweden). The SX1 screening panel detects 8 allergen-specific IgE antibodies: against house dust mite (Dermatophagoides pteronyssinus), cat, dog, birch, timothy (Phleum pratense), rye, ragweed, Cladosporium herbarum.
+ Open protocol
+ Expand
5

Measuring Af-specific IgG (Gm3) Levels

Check if the same lab product or an alternative is used in the 5 most similar protocols
Af-specific IgG (Gm3) concentration was measured in our routine laboratory by the commercial ImmunoCAP system (Phadia, Thermo Fisher Scientific, USA), which uses automated fluorescent enzyme immunoassay (FEIA) technology. The m3 antigen is a crude extract from whole Af conidia and mycelia. According to manufacturer data, the reference value is <39 mg/L.
+ Open protocol
+ Expand
6

Assessing IgE Sensitization in Pediatric Asthma

Check if the same lab product or an alternative is used in the 5 most similar protocols
IgE-mediated immune reactions are the most common cause of antigen-induced pediatric asthma. Total IgE and allergen-specific serum IgE, our study inclusion factors (Table 1), were assessed using the ImmunoCAP System (Thermo Fisher Scientific/Phadia AB, Uppsala, Sweden). The cut-off level was 60 kU/L. In the asthma group, total IgE was greater than 60 kU/L. IgE Serology atopic sensitization was indicated if the child had allergen–specific serum IgE ≥ 0.35 kU/L. We tested allergen-specific serum IgE on dust mite and food allergens of Fx5 (egg white, milk, fish, wheat, peanut, and soy) (22 (link)).
+ Open protocol
+ Expand
7

Measuring Dpt and Dfa-specific IgE

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum was analyzed for total Dermatophagoides pteronyssinus (Dpt)—specific I and Dermatophagoides farinae (Dfa)—specific IgE by the ImmunoCAP system (Thermo Fisher Scientific, Dreieich, Germany).
+ Open protocol
+ Expand
8

Quantifying Allergen-Specific IgE in Children

Check if the same lab product or an alternative is used in the 5 most similar protocols
We measured sIgE levels for cow’s milk extract and egg white on an ImmunoCAP system (UniCAP®, Thermo Fisher Scientific, Waltham, MA, USA) with the appropriate allergen caps according to manufacturer instructions. Milk-specific sIgE values were considered positive if they were >15 kU/L in children aged ≥1 year and 5 kU/L in those aged < 1 year [21 ]. Egg-specific IgE values were considered positive if they were >7 kU/L in children aged ≥2 years and 2 kU/L in those aged <2 years [21 ].
+ Open protocol
+ Expand
9

Measuring Allergen-Specific IgE Levels

Check if the same lab product or an alternative is used in the 5 most similar protocols
Allergen-specific immunoglobulin E (IgE) was measured against house dust mite, cat, and timothy grass. Analysis was performed in a single central laboratory (AMC Amsterdam) using the ImmunoCAP system (Thermo Fisher Scientific, Uppsala, Sweden). The assay was calibrated against the WHO standard for IgE with a range of 0.35–100 kU/l. A positive IgE was defined as ≥ 0.35 kU/l for one or more of house dust mite, cat, and timothy grass. In this study, data on IgE sensitisation were available only from 3542 subjects.
+ Open protocol
+ Expand
10

Serum IgE Levels for Respiratory Allergies

Check if the same lab product or an alternative is used in the 5 most similar protocols
A serum sample was collected from all participants in order to investigate the total IgE level in their blood, as well as some specific IgEs for respiratory allergies (tree pollen, grass pollen, and house dust mite). Blood samples were collected at the Antwerp University Hospital by a responsible nurse. Total and specific IgEs were quantified by an ImmunoCAP System (Thermo Fisher Scientific, Uppsala, Sweden). All assays were performed and results interpreted according to the manufacturers’ recommendation. Total IgE counts below 114 kU/l were considered as non-allergic. For specific IgE counts, values below 0.35 kUA/l were considered as non-allergic.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists