Thyroid and Metabolic Biomarkers Measurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
Venous blood samples were collected using routine methods between 0700 h and 0930 h after overnight fasting. TT4, FT4, TT3, FT3, and TSH were measured with an Advia Centaur XP immunity analyzer (Siemens Corporation) and thyroid autoantibodies (TPO-Ab and TG-Ab) were measured with a Roche electrochemical immunity analyzer (E170). FPG, fasting insulin, TG, and HDL-c were measured with an Olympus AU4500 automatic chemistry analyzer (Olympus Corporation, Tokyo, Japan). The homeostasis model assessment (HOMA) index for IR (HOMA-IR) was calculated as fasting insulin (mU/L) times FPG (mmol/L) divided by 22.5.
+ Open protocol
+ Expand
2

Anthropometric and Metabolic Evaluation

Check if the same lab product or an alternative is used in the 5 most similar protocols
After an overnight fast, all participants underwent a detail anthropometric evaluation including height (m), weight (kg), systolic pressure (SDP), and diastolic pressure (DBP) at 8:00 am. All of these were measured twice during the examination, and the averages of these data were used for further analysis. Body mass index (BMI) was calculated as weight/height2.
Venous blood samples were drawn after a fasting period of 12h. Serum triglyceride (TG), total cholesterol (TC), low-density lipoprotein cholesterol (LDL-c), high- density lipoprotein cholesterol (HDL-c), fasting glucose (FG) and uric acid (UA) levels were measured using an Olympus AU4500 automatic chemistry analyzer (Olympus Corporation, Tokyo, Japan). Definition of metabolic disorders was shown in Table 3. Thyroid ultrasound examination was performed by specific thyroid experts using a 10-MHz liner array probe (Logiq 5 Pro, GE Medical systems, USA). For each nodule, size (length, width, and depth), location, number, echogenicity, boundary, and cystic component were collected and recorded. We recorded greatest nodule dimension as TN diameter. According to these results, subjects were divided into TN present group and TN absent group. The normal UA group are subjects with UA < 420μmol/L for men and < 360μmol/L for women. Otherwise, subjects were included into the high UA group.
+ Open protocol
+ Expand
3

Fasting Blood Biomarkers Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Samples of venous blood were obtained between 6:00 and 8:00 am after overnight fasting. Triglycerides, total cholesterol, fasting plasma glucose, LDL-c, and HDL-c levels were determined with an AU4500 automatic chemistry analyzer (Olympus Corporation, Tokyo, Japan). Glycated hemoglobin (HbA1c) was measured with a TOSOH HLC-723G8 automatic glycohemoglobin analyzer (Tosoh Corporation, Yamaguchi, Japan) and fasting C-peptide with an ADVIA Centaur XP immunoassay System (Siemens Inc., Munich, Germany).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!