Invenio r ftir spectrometer

Manufactured by Bruker
Sourced in Germany

The INVENIO R FTIR spectrometer is a Fourier Transform Infrared Spectrometer designed for analytical applications. It provides high-resolution infrared spectroscopy capabilities for various materials analysis tasks.

Automatically generated - may contain errors

4 protocols using invenio r ftir spectrometer

1

In Situ FTIR Spectroscopy of Silica Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
IR measurements were carried out in the transmission mode. Aliquots of the sample particles were pressed in self-supporting pellets and placed in a quartz cell equipped with CaF2 windows. The FTIR spectra were recorded with a Bruker INVENIO R FTIR spectrometer (liquid nitrogen cooled MCT detector; resolution, 4 cm−1) by averaging 128 scans to attain a good signal-to-noise ratio. The cell was attached to a conventional vacuum line (residual pressure ≤ 1 × 10−4 mbar) allowing adsorption–desorption experiments to be carried out in situ. As detailed previously [22 (link)], the silica samples underwent an hydrogen/deuterium (H/D) isotopic exchange by adsorption/desorption of D2O (99.90% D) to convert surface silanols (☰SiOH) in the ☰SiOD form.
+ Open protocol
+ Expand
2

Electrochemical ATR-SEIRAS of Oxygen Reactions

Check if the same lab product or an alternative is used in the 5 most similar protocols
The electrochemical ATR-SEIRAS measurements were carried out on a BRUKER INVENIO-R FTIR spectrometer equipped with a mercury cadmium telluride (MCT) detector cooled with liquid nitrogen in O2-saturated aqueous solutions of 0.1 M KOH and 0.1 M HClO4. Three-electrode configuration was utilized for electrochemical control, in which the Hg/HgO electrode and saturated calomel electrode (SCE) were used as the reference electrodes in alkaline and acid electrolytes, respectively; a Pt foil was used as the counter electrode. Unpolarized infrared radiation from an Elema source was focused at the interface at the incident angle of 60°, and the reflected radiation was detected. Real-time spectra with a resolution of 8 cm−1 were recorded during stepping the working electrode potential, and each spectrum was integrated by 44 scans. All spectra are shown in the absorbance units −log(R/R0), where R and R0 represent the reflected intensity of the sample and reference spectrum, respectively. Reference spectra were taken at 1.1 V vs RHE.
+ Open protocol
+ Expand
3

FTIR Spectroscopy of Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
FTIR spectroscopy of the samples was collected using a Germany Bruker INVENIO-R FT-IR spectrometer. To gain an acceptable signal-to-noise ratio, 128 scans with a resolution of 4 cm−1 have been accumulated. ATR spectrum uses diamond reflection crystal.
+ Open protocol
+ Expand
4

FTIR Spectroscopy of Carbon Quantum Dot Hybrids

Check if the same lab product or an alternative is used in the 5 most similar protocols
The FTIR spectrum of CQD was recorded using a Bruker Invenio R FTIR spectrometer (Bruker, Mannheim, Germany) using an attenuated total reflection (ATR) accessory with a diamond crystal. The resulting spectrum was obtained by averaging 20 scans with a spectral resolution of 4 cm–1.
The FTIR spectra of hybrids were obtained at Nicolet8700 (Thermo Fisher Scientific; Waltham, MA, USA) using an ATR accessory with a diamond crystal. To obtain the FTIR spectra, the spectrometer configuration with a XT-KBr beam splitter and liquid nitrogen cooled mercury cadmium telluride (MCT-A) detector was used. For the solutions under investigation, the spectra were obtained in the region 650–4000 cm−1 with a resolution of 4 cm−1. In the obtained spectra, the Blackman–Harris apodization function was used and the Mertz phase correction was applied. Due to the low concentration of the investigated substances, the subtraction of the contribution of CQD in isopropanol (see Figure S1) was performed using Origin 9 (OriginLab Co., Northampton, MA, USA) software. Such mathematical procedures reveal any possible interaction between components of hybrids.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!