The largest database of trusted experimental protocols

Seven easy ph

Manufactured by Mettler Toledo
Sourced in Switzerland

The Seven Easy pH is a benchtop pH meter designed for routine pH measurements. It features a large, easy-to-read display and intuitive controls for straightforward operation. The instrument provides accurate and reliable pH readings, making it a suitable choice for a variety of laboratory applications.

Automatically generated - may contain errors

34 protocols using seven easy ph

1

Sausage Homogenate pH Determination

Check if the same lab product or an alternative is used in the 5 most similar protocols
The pH values of a sausage homogenate prepared with 3 g of sausage sample and 27 mL of distilled water were determined using a digital pH meter (SevenEasy pH, Mettler-Toledo AG, Switzerland) equipped with an electrode calibrated with phosphate buffer at pH 4.0 and pH 7.0 at room temperature.
+ Open protocol
+ Expand
2

Meat Batter Color and pH Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The instrumental surface color of each meat batter was determined by using chroma-meter (CR-400, Konica Minolta Sensing Inc., Osaka, Japan) measuring lightness (Commission Internationale de l’Eclairage [CIE] L*-value), redness (CIE a*-value) and yellowness (CIE b*-value); illuminate C was calibrated with a white standard plate (Y = 93.6, X = 0.3134, y = 0.3194). Chroma (C*) was measured using data processing equipment (DP-400, Konica Minolta Sensing Inc., Japan). The color measurement was performed 5 times on each batter sample. To measure the pH, a homogenizer (PH-91, SMT Co., Chiba, Japan) was used to homogenize 5 g of each batter in 50 mL of distilled water for 1 min at 10,000 rpm. The pH values were recorded in triplicate using a pH meter (SevenEasy pH, Mettler-Toledo GmbH, Schwerzenbach, Switzerland).
+ Open protocol
+ Expand
3

Measuring pH in Chicken Breast Slurry

Check if the same lab product or an alternative is used in the 5 most similar protocols
The pH value was measured in triplicate on chicken breast slurry samples, after homogenization of 5 g with 45 mL of distilled water in a homogenizer (PH91; SMT Co., Ltd., Tokyo, Japan). Steadily stirred slurry samples were measured using a pH meter probe (Seven Easy pH; Mettler-Toledo GmbH, Schwerzenbach, Switzerland) that had previously been calibrated.
+ Open protocol
+ Expand
4

Meat Slurry pH and Color Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The pH of meat slurry was measured at room temperature using a pH meter (SevenEasy pH, Mettler-Toledo GmbH, Giessen, Switzerland). A 10 g of each sample was homogenized with 100 mL of distilled water at 10,000 rpm for 60 s using a homogenizer (PH91, SMT Co. Ltd., Tokyo, Japan). The instrumental Commission internationale de l’éclairage (CIE) color of samples, including lightness (CIE L*), redness (CIE a*), yellowness (CIE b*), chroma and hue angle, were measured using a color difference meter (CR-400, Konica Minolta Sensing Inc., Tokyo, Japan). The color meter was standardized using a white plate (Illuminant C: Y = 93.6, x = 0.3134, and y = 0.3194). Ten times random measurements were taken for each sample.
+ Open protocol
+ Expand
5

pH Determination of Food Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
The pH value was determined briefly by mixing 5 g sample with 45 mL of distilled
water in a homogenizer (PH91, SMT Chiba, Japan) at 10,000 rpm, 1 minute. The pH
value was then recorded by a pH meter (Seven Easy pH, Mettler-Toledo GmbH,
Greifensee, Switzerland) that was calibrated by using technical buffer solutions
at different pH (4.01, 9.00, and 7.00).
+ Open protocol
+ Expand
6

Preparation and Characterization of Bioactive Dairy Yogurt

Check if the same lab product or an alternative is used in the 5 most similar protocols
We prepared 2 types of yogurts, normal yogurt (Nyogurt) and DSW-containing yogurt (DSW-yogurt). The N-yogurt was manufactured as follows: 70% fresh market cow milk was mixed with 3% skim milk powder (calorie, 3,550 kcal/kg; carbohydrate, 52%; fat, 1%; protein, 35%; Ca, 1.1%; Na, 0.6%; Seoul Dairy Cooperative, Seoul, Korea), 3% glucose, and 24% deionized water, sterilized at 95°C for 15 min and cooled to 40°C. Then, 0.025% (wt/wt) lactase (Ha-Lactase, Chr. Hansen A/S, Hørsholm, Denmark) and 2% (wt/wt) starter culture were added; we used salt-resistant lactic acid bacteria (LAB; Lactobacillus pentosus and Pediococcus pentosaceus) in consideration of the salt contained in DSW. The mixture was fermented at 38°C for 12 h.
In DSW-yogurt, 10% DSW instead of 10% deionized water was used; otherwise, the process was the same. The final products were stored at 4°C until use. The pH value of N-yogurt and DSW-yogurt was measured using a pH meter (SevenEasy pH, Mettler-Toledo AG, Zurich, Switzerland) equipped with an electrode (InLab Expert Pro, Mettler-Toledo AG). Their LAB population was determined by culture in MRS agar containing 0.02% sodium azide. Both yogurts had same pH value (4.5) and LAB count (9.1 log 10 cfu/g).
+ Open protocol
+ Expand
7

Homogenization and pH Measurement of Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
Sample (5 g) in triplicate was added with 45 mL of distilled water (DW) and homogenized at 10,000 rpm for 60 s using a homogenizer (PH91, SMT Co., Ltd., Chiba, Japan). The pH value of the homogenized sample was recorded using a pH meter calibrated with acid (pH 4.01) and neutral (pH 7.00) technical buffer solutions (Seven Easy pH, Mettler-Toledo GmbH, Greifensee, Switzerland) at 22°C according to manufacturer’s instruction.
+ Open protocol
+ Expand
8

Meat Quality Analysis: pH and Water Holding Capacity

Check if the same lab product or an alternative is used in the 5 most similar protocols
The pH was measured in triplicate, sample (5 g) was combined with 45 mL of distilled water then homogenized at 10,000 rpm for 60 s using a homogenizer (PH91, SMT Co., Ltd., Chiba, Japan). The pH value of the meat slurry was recorded using a pH meter calibrated with acid (pH 4.01) and neutral (pH 7.00) technical buffer solutions with an automatic temperature compensation program (SevenEasy pH, Mettler-Toledo GmbH, Greifensee, Switzerland).
The WHC was determined according to the method from Kristensen and Purslow [12 (link)] with modifications. The WHC was defined as the proportion (%) of remaining moisture per total original moisture content of fresh ground sample. Briefly, 5 g of ground sample was weighed into graduated centrifuge tubes and prepared in triplicate. The tube was sealed and heated for 30 min in a 75°C water bath. The tubes were cooled in a chilling room (2°C±2°C) for 30 min then centrifuged at 980 g at 4°C for 10 min. The supernatant was decanted and measured, and the moisture contents of both raw sample and supernatant were determined according to the AOAC method [13 ].
+ Open protocol
+ Expand
9

Homogenization and pH Determination

Check if the same lab product or an alternative is used in the 5 most similar protocols
Homogenated samples in triplicate were prepared from 5 g of perfectly ground
sample added with 45 mL of distilled water assisted by homogenizer (PH91; SMT,
Tokyo, Japan). The pH value was determined by a previously calibrated pH meter
probe (Seven Easy pH; Mettler-Toledo GmbH, Schwerzenbach, Switzerland).
+ Open protocol
+ Expand
10

pH Measurement of Homogenized Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
The pH value was tested for the homogenized samples in triplicate. After mixing 5
g sample with 45 mL of distilled water in a homogenizer (PH91, SMT, Tokyo,
Japan), the pH of stirred slurry samples was measured using a pH meter probe
(Seven Easy pH, Mettler-Toledo GmbH, Schwerzenbach, Switzerland) that had
previously been calibrated.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!