Immage automatic immunoassay system

Manufactured by Beckman Coulter

The IMMAGE automatic immunoassay system is a laboratory instrument designed for the automated detection and measurement of various analytes in biological samples. It utilizes immunoassay technology to perform quantitative analysis of proteins, hormones, and other molecules of clinical importance.

Automatically generated - may contain errors

4 protocols using immage automatic immunoassay system

1

Biomarker Measurement in Fasting Plasma

Check if the same lab product or an alternative is used in the 5 most similar protocols
Fasting blood samples were drawn from each participant and transferred on ice to center laboratory for analysis. An IMMAGE automatic immunoassay system (Beckmann-Coulter) was used to examine plasma level of Hs-CRP. Intra-assay variability coefficient lied between 3.5-5.0%, and inter-assay variability coefficient between 4.0-7.5%, and limited detection level was 0.2 mg/L. APN was measured by a high sensitivity Human adiponectin ELISA kit (BioCat GmbH) with intra-assay variability coefficient lied between 4.0-5.5% and inter-assay variability coefficient between 5.0-7.5%. Triglyceride (TG), total cholesterol (TC), low density lipoprotein-cholesterol (LDL-C), high density lipoprotein-cholesterol (HDL-C) and fasting blood glucose were also measured by Automatic Biochemistry Analyzer (Beckman coulter UniCel DxC 800 Synchron).
+ Open protocol
+ Expand
2

Metabolic and Inflammatory Markers in Cardiometabolic Diseases

Check if the same lab product or an alternative is used in the 5 most similar protocols
Laboratory parameters were assessed using standard analytical methods. Hypertension was diagnosed by a systolic/diastolic blood pressure >140/90 mmHg and or a prescribed anti-hypertensive treatment and T2D was diagnosed by a fasting blood glucose > 7.0 mmol/l, a random glucose measurement > 11.0 mmol/l or a HbA1c > 6.5% or a prescribed glucose-lowering drug, both defined according to the American Diabetes Association criteria.
Blood samples were collected after an overnight fast. Fasting serum glucose, triglycerides, and HbA1c were measured using enzymatic methods. Fasting serum insulin and C-peptide were measured using a chemiluminescence assay (Insulin Architect, Abbott). High-sensitivity C-reactive protein (CRP) was measured using an IMMAGE automatic immunoassay system (Beckman-Coulter) and high-sensitivity interleukin 6 (hs-IL-6) was measured using the Human IL-6 Quantikine HS ELISA Kit (R&D Systems). IFN-γ–induced protein 10 (IP-10), interleukin 7 (IL-7), macrophage migration inhibitory factor (MIF), C-X-C motif chemokine ligand 2 (CXCL2), and 5 (CXCL5) were measured by using a Luminex assay (ProcartaPlex Mix&-Match Human 13-plex; eBioscience, San Diego, CA, USA).
+ Open protocol
+ Expand
3

Comprehensive Obesity Assessment Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Subjects underwent systematic explorations that included a thorough medical interview recording obesity comorbidities such as type 2 diabetes, a routine physical examination and fasting biological measurements as previously described.18 21 Blood samples were collected after an overnight fast. Fasting glucose, high density lipoprotein cholesterol (HDL-c), triglycerides and haemoglobin A1c (HbA1c) were measured using enzymatic methods. Fasting serum insulin was measured using a chemiluminescence assay (Insulin Architect, Abbott). Serum leptin was measured using the Human Leptin Quantikine ELISA Kit (R&D Systems, Inc). High-sensitivity c-reactive protein was measured using an IMMAGE automatic immunoassay system (Beckman-Coulter).
Weight and height were assessed during the clinical inclusion visit according to standardised procedures using the same scale for all subjects. Body composition was assessed using the same device; a whole-body fan-beam DXA scan (Hologic Discovery W, software V.12.6, 2; Hologic, Bedford, Massachusetts) which evaluated per cent body fat mass. BFMI was calculated as body fat (kg)/height (m2).
+ Open protocol
+ Expand
4

Biomarker Evaluation in Fasting Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood samples were collected after an overnight fast. Fasting serum glucose, triglycerides, and HbA1c were measured using enzymatic methods. Fasting serum insulin and C-peptide were measured using a chemiluminescence assay (Insulin Architect, Abbott). High-sensitivity C-reactive protein (hs-CRP) was measured using an IMMAGE automatic immunoassay system (Beckman-Coulter) and high-sensitivity interleukin 6 (hs-IL-6) was measured using the Human IL-6 Quantikine HS ELISA Kit (R&D Systems). IFN-γ–induced protein 10 (IP-10), interleukin 7 (IL-7), C-X-C motif chemokine ligand 2 (CXCL2), and 5 (CXCL5) were measured by using a Luminex assay (ProcartaPlex Mix&Match Human 13-plex; eBioscience, San Diego, CA, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!