The largest database of trusted experimental protocols

Imagestudio odyssey clx software

Manufactured by LI COR

The ImageStudio Odyssey CLx software is a tool used for analyzing and quantifying data from the Odyssey CLx imaging system. It provides users with the ability to process, analyze, and visualize fluorescence-based data collected from the Odyssey CLx instrument.

Automatically generated - may contain errors

2 protocols using imagestudio odyssey clx software

1

Western Blot Protein Analysis Workflow

Check if the same lab product or an alternative is used in the 5 most similar protocols
Protein extracts were prepared by boiling cells in lysis buffer (125 mM Tris-HCl pH 6.8, 20% (w/v) glycerol, 4% SDS) for 10 minutes. Lysates were then mixed with Laemmli buffer and subjected to an additional boiling step. Approximately 15–20 μg of protein were loaded onto either 10% in-house acrylamide gels or 4–20% Mini-PROTEAN Tris-Glycine Precast Protein Gels (BioRad). Samples were then transferred to an Immobilon-FL Transfer PVDF Membrane (Millipore) for 2 hours at 4°C and 70V.
To block nonspecific binding, membranes were incubated in 5% BSA-TBS for 1 hour at room temperature. This was followed by an overnight incubation with primary antibodies at 4°C in 5% BSA-TBS with 0.1% Tween20. Afterwards, membranes were washed three times in TBS with 0.1% Tween20. And incubated with the corresponding IRDye-conjugated secondary antibody in 5% BSA-TBS with 0.1% Tween20. After three washes with buffer, membranes were dried and subjected to analysis using the Odyssey CLx system and ImageStudio Odyssey CLx software (LI-COR BIOSCIENCES, Lincoln, NE), following the manufacturer’s protocols.
+ Open protocol
+ Expand
2

Protein Extraction and Western Blot

Check if the same lab product or an alternative is used in the 5 most similar protocols
For protein extractions, cell pellets were resuspended in RIPA buffer (20 mM Tris-HCl (pH 7.5), 150 mM NaCl, 1% NP-40 y 1% sodium deoxycholate) supplemented with protease inhibitors and incubated on ice for 30 min with constant agitation. The lysate was then centrifuged at 14,000 rpm for 10 min at 4°C. The supernatant was sonicated using a Bioruptor (Diagenode, UCD-200) for 1 cycle of 3 minutes (high power, 30 s on, 30 s off). Protein concentration was determined by Bradford assay (Applied Biochem, A6932). 20 μg of protein was loaded into home-made 10% polyacrylamide gel with SDS or 4%–20% Mini-PROTEAN tris-Glycine Precast Protein Gels (Biorad, 4561096) and electroblotted onto Immobilon-FL Transfer Membranes (Millipore), after 5 minutes methanol activation. Membranes were then blocked in Odyssey Blocking Buffer (LI-COR Biosciences, 927-40000) for 1 hour and then probed with required primary antibodies for 2 hours. Membranes were washed with 0.1% Tween-20 - Odyssey Blocking Buffer and incubated with corresponding secondary antibodies (conc: 1:10.000) for 1 hour and finally, membranes were washed again with 0.1% Tween-20 - Odyssey Blocking Buffer. Membrane were analyzed using Odyssey CLx and ImageStudio Odyssey CLx Software (LI-COR BIOSCIENCES, Lincoln, NE) according to the manufacturer’s protocols.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!