The largest database of trusted experimental protocols

7200 gcqtof ms

Manufactured by Agilent Technologies
Sourced in United States

The 7200 GCqTOF MS is a gas chromatography-quadrupole time-of-flight mass spectrometer. It is a high-resolution analytical instrument designed for the identification and quantification of chemical compounds.

Automatically generated - may contain errors

2 protocols using 7200 gcqtof ms

1

Quantitative Determination of α-Ketoglutarate in Serum by GC/MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
Aplha-ketoglutarate was quantitatively determined in serum samples by GC/MS at the Centre for Omic Sciences (Rovira i Virgili University). The methodology used has been reported elsewhere [10 (link)]. Samples were analysed in a 7890A Series gas chromatograph coupled to a 7200 GCqTOF MS (Agilent Technologies, Santa Clara, U.S.A.). The chromatographic column was a J&W Scientific HP5-MS (30 m x 0.25 mm i.d., 0.25 μm film) (Agilent Technologies). The calibration curve showed good linearity in the studied range of 0.13 to 10 mg/L, with a determination coefficient (R2) of 0.9993. The extraction recovery was 99.7%, while accuracy was 101.7%. The intraday and interday precision had a relative standard deviation of, respectively, 4.1% and 4.8% (RSD, n = 3). MDL was 0.05 mg/L, while MQL was 0.13 mg/L.
+ Open protocol
+ Expand
2

Quantitative analysis of primary metabolites

Check if the same lab product or an alternative is used in the 5 most similar protocols
Relative levels of primary metabolites were measured as described in Hasler-Sheetal et al. (2016) (link). In brief, 50-mg FW samples (2nd leaves from 4-month-old plants) from six independent T0 CBM20-expressing plants and six vector control plants were extracted for 2 min in an ultrasound bath followed by 15 min on a thermo-shaker (both at 4°C) in 1 ml methanol/acetonitrile/water (4:4:2 v/v/v) chilled to –20°C and spiked with 0.4 mg l–1 13C6 sorbitiol and reserpine as internal standards. After centrifugation at 16 000 g for 5 min, the relative metabolite levels were analysed by GC-quadrupole time-of-flight MS (7200 GC-QTOF MS, Agilent Technologies).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!