Ipds 2t
The IPDS 2T is a compact and versatile lab equipment designed for precision measurements. It functions as a high-resolution imaging system capable of capturing detailed images and data. The core function of the IPDS 2T is to provide accurate and reliable data acquisition for various research and analytical applications.
Lab products found in correlation
6 protocols using ipds 2t
X-ray Analysis of Metal Complexes
X-Ray Structural Analysis of 2c Crystal
single crystal of
coated with paraffin oil. X-ray single-crystal structural data were
collected at low temperature (170 K) using a STOE IPDS 2T diffractometer
equipped with a normal-focus, 2.4 kW, sealed-tube X-ray source with
graphite-monochromated Mo Kα radiation (λ = 0.71073 Å).
The program X-Area was used for integration of the diffraction profiles;
numerical absorption correction was made with the programs X-shape
and X-red32; all from STOE 2010. The structure was solved by SHELXT-201426 (link) and refined by full-matrix least-squares methods
using SHELXL-2013.27 (link) The nonhydrogen atoms
were refined anisotropically. Hydrogen atoms were refined isotropically
on calculated positions using a riding model with their Uiso values
constrained to 1.2 Ueq of their pivot atoms. All calculations were
carried out using SHELX-201327 (link) and the
WinGX GUI, ver2013.2.28 (link) The crystallographic
data are summarized in
The crystallographic data were deposited with the
Cambridge Crystallographic
Data Centre (CCDC) 12 Union Road, Cambridge CB21EZ, U.K. These data
can be obtained free of charge on quoting the depository number CCDC
1544200 by FAX (+44-1223-336-033), e-mail (
Single Crystal Structure of Compound 6
X-ray Structural Analysis Protocol
Structure Determination via X-ray Crystallography
Chiral HPLC Separation and Characterization of (14S/15R)-14-deoxyoxacyclododecindione
The polarimeter values were measured with a Perkin-Elmer 241 polarimeter at 546 nm and 578 nm. The data were extrapolated to a wavelength of λ = 589 nm by using the Drude equation. 23 Crystallization was performed by the solvent diffusion method using ethyl acetate and petroleum ether.
X-ray crystallography of (+)-4 was performed on a STOE IPDS 2T with Mo-K α radiation (graphite monochromator).
CCDC 1454207 contains the supplementary crystallographic data for (14S/15R)-14-deoxyoxacyclododecindione (+)-4.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!